| AEBD |
TOLERANCE OF TEMP COEFFICIENT IN PPM PER DEG CELSIUS |
-900.0/+900.0 SINGLE SECTION |
| AFWY |
TERMINAL THICKNESS |
0.006 INCHES NOMINAL |
| ABPM |
BODY DIAMETER |
0.390 INCHES NOMINAL |
| ADAU |
BODY HEIGHT |
0.125 INCHES NOMINAL |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 PRINTED CIRCUIT |
| AEBS |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER |
0.330 INCHES NOMINAL |
| CQJJ |
NONDERATED OPERATING TEMP |
-20.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
| ABJT |
TERMINAL LENGTH |
0.150 INCHES NOMINAL |
| AFWW |
TERMINAL WIDTH |
0.064 INCHES NOMINAL |
| AXGR |
ADJUSTMENT DEVICE TORQUE |
0.200 INCH-OUNCES MINIMUM AND 2.000 INCH-OUNCES MAXIMUM |
| AEBC |
TEMP COEFFICIENT OF CAPACITANCE IN PPM PER DEG CELSIUS |
-1500.0 SINGLE SECTION |
| CTGR |
ADJUSTMENT DEVICE DRIVE TYPE AND QUANTITY |
1 SQUARE HOLE |
| AAQL |
BODY STYLE |
ROTARY |
| AXGT |
INSULATION DC RESISTANCE AT 25 DEG CELSIUS |
10000.0 MEGOHMS |
| AKNA |
INCLOSURE TYPE |
ENCASED |
| AECJ |
QUALITY FACTOR AT 25 DEG CELSIUS |
1000.0 |
| CTGN |
CAPACITANCE RANGE IN PICOFARADS |
+20.0/+100.0 SINGLE SECTION |
| AGAV |
END ITEM IDENTIFICATION |
RADIO SET AN/ARC-190 |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 TERMINAL |
| AEBX |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO DIAMETER |
0.330 INCHES NOMINAL |
| CTGP |
NONDERATED VOLTAGE RATING AND TYPE |
400.0 DC CONTINUOUS SINGLE SECTION |