5910-01-173-1094 ( 196D475X0025KA1 , 184-9092-150 , 41DS475B035K1A , DNS475B035KR , 4500-3470 , 0180-0630 , D4R7GA35M , 051055-006 , CX12N475K , 196-D475X9020 PE , T368B475K050AS , 199D475X0035DB1 , DIT4R7F35 , MIL-C-49137/2 )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5910-01-173-1094 | 5910 | 011731094 | CAPACITOR,FIXED,ELECTROLYTIC | 0000 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 6.0000 |
| CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 50.0 DC SINGLE SECTION |
| CQBQ | CAPACITANCE VALUE PER SECTION | 4.700 MICROFARADS SINGLE SECTION |
| ABHP | OVERALL LENGTH (NON-CORE) | 0.500 INCHES MAXIMUM |
| ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-C-49137/2 GOVERNMENT SPECIFICATION |
| CWQH | DC LEAKAGE AT REFERENCE TEMP | 2.500 MICROAMPERES |
| AECE | ANODE TYPE | SOLID |
| ADAQ | BODY LENGTH | 0.500 INCHES MAXIMUM |
| CRTP | TOLERANCE RANGE PER SECTION | -10.00/+10.00 PERCENT SINGLE SECTION |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKW | OVERALL HEIGHT (NON-CORE) | 0.250 INCHES MAXIMUM |
| ABMK | OVERALL WIDTH (NON-CORE) | 0.250 INCHES MAXIMUM |
| AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
| CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
| AEBT | TERMINAL DIAMETER | 0.020 INCHES NOMINAL |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
| ABJT | TERMINAL LENGTH | 0.187 INCHES NOMINAL |
| TEST | TEST DATA DOCUMENT | 81349-MIL-C-49137 SPECIFICATION |
| AECQ | ELECTRICAL POLARIZATION | POLARIZED |
| ABPM | BODY DIAMETER | 0.250 INCHES MAXIMUM |
| AEBS | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER | 0.125 INCHES NOMINAL |
| CWNJ | CAPACITIVE ELECTRODE MATERIAL | TANTALUM |
| CWJK | CASE MATERIAL | PLASTIC |
| AAQL | BODY STYLE | W/O MTG FACILITIES, TERMINAL(S) ON ONE END |
| CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| 196D475X0025KA1 | 56289 | A | 1 | C | AC | 1 | ZZ |
| 184-9092-150 | 13499 | A | 1 | C | AC | 6 | ZZ |
| 41DS475B035K1A | 56699 | A | 1 | C | AW | 6 | TX |
| DNS475B035KR | 26769 | A | 1 | C | AC | 6 | ZZ |
| 4500-3470 | 24655 | A | 1 | C | AC | 6 | ZZ |
| 0180-0630 | 28480 | A | 1 | C | AC | 6 | ZZ |
| D4R7GA35M | 12954 | A | 1 | C | AC | 6 | ZZ |
| 051055-006 | 05159 | A | 1 | C | AC | 6 | ZZ |
| CX12N475K | 81349 | M | 2 | 2 | E | TX | |
| 196-D475X9020 PE | 56289 | A | 1 | C | AC | 6 | ZZ |
| T368B475K050AS | 05397 | F | 8 | E | 3 | TX | |
| 199D475X0035DB1 | 56289 | A | 1 | C | AC | 6 | ZZ |
| DIT4R7F35 | 24138 | H | 1 | C | AC | 1 | ZZ |
| MIL-C-49137/2 | 81349 | M | 1 | 4 | E | TX |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| 196D475X0025KA1 | 56289 | SPRAGUE ELECTRIC CO | A | A |
| 184-9092-150 | 13499 | ROCKWELL COLLINS INC. | F | A |
| 41DS475B035K1A | 56699 | BC COMPONENTS | A | A |
| DNS475B035KR | 26769 | SPRAGUE PALM BEACH INC | A | A |
| 4500-3470 | 24655 | GENRAD INC | A | A |
| 0180-0630 | 28480 | HEWLETT PACKARD CO | A | A |
| D4R7GA35M | 12954 | MICROSEMI CORP.-SCOTTSDALE | A | A |
| 051055-006 | 05159 | COHU INC | A | A |
| CX12N475K | 81349 | MILITARY SPECIFICATIONS | A | M |
| 196-D475X9020 PE | 56289 | SPRAGUE ELECTRIC CO | A | A |
| T368B475K050AS | 05397 | UNION CARBIDE CORP MATERIALS SYS | A | F |
| 199D475X0035DB1 | 56289 | SPRAGUE ELECTRIC CO | A | A |
| DIT4R7F35 | 24138 | INTERNATIONAL ELECTRONICS CORP | A | H |
| MIL-C-49137/2 | 81349 | MILITARY SPECIFICATIONS | A | M |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| A | X | A | 1 | 02/29/1 | P | 8532290040 | 0000 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DF | N | SF9EH-V | F | ||
| DS | N | I | |||
| DM | Z | 15B2--1 | M | 0 | REVERSAL OF PHRASE CODE Z 5910-00-197-0253 |
| GP | ------- | C | |||
| DN | 9B----- | N | |||
| DA | Z | Q2200X- | A |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| A | A | P | X |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DA | SMS | Z | 0 | EA | 0 | U | Z | Q2200X- | A |
| GP | SMS | Z | 0 | EA | 0 | U | ------- | C | |
| DF | SMS | Z | 0 | EA | 0 | U | SF9EH-V | F | |
| DS | SMS | Z | 0 | EA | 0 | U | D | ||
| DN | SMS | Z | 0 | EA | 0 | U | 9B----- | N | |
| DM | SMS | Z | 0 | EA | 0 | U | Z | 15B2--1 | M |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|---|---|---|---|
| Q | 2 | 2 | 00 | X |
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 061400 | X | 34450 | P | 72D | Z | 9 | A | H | Z | CONDENSERS/PARTS NOI/CAPACITORS |