5910-01-206-4308 ( DB44BY2R0C , DB44BY2R0D , 117620 , DB44BY2R0C )

NSN Information
NSN FSC NIIN Item Name INC
5910-01-206-4308 5910 012064308 CAPACITOR,FIXED,CERAMIC DIELECTR 0000
NSN Features
MRC Parameter Characteristics
CRHD TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS -30.0/+30.0 SINGLE SECTION
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.100 INCHES NOMINAL
CQJJ NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
ABHP OVERALL LENGTH (NON-CORE) 0.150 INCHES MAXIMUM
CWPK INSULATION RESISTANCE AT REFERENCE TEMP 1000.0 MEGOHM-MICROFARADS
ADAT BODY WIDTH 0.150 INCHES MAXIMUM
CWPM DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 0.1500
AEBT TERMINAL DIAMETER 0.016 INCHES NOMINAL
AARG RELIABILITY INDICATOR NOT ESTABLISHED
CRTP TOLERANCE RANGE PER SECTION -0.25/+0.25 PICOFARADS SINGLE SECTION
CQBQ CAPACITANCE VALUE PER SECTION 2.000 PICOFARADS SINGLE SECTION
ABJT TERMINAL LENGTH 1.500 INCHES MINIMUM
AAQL BODY STYLE W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
ABKW OVERALL HEIGHT (NON-CORE) 0.100 INCHES MAXIMUM
AEBZ SCHEMATIC DIAGRAM DESIGNATOR NO COMMON OR GROUNDED ELECTRODE(S)
CQLZ TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS 0.0 SINGLE SECTION
ADAU BODY HEIGHT 0.100 INCHES MAXIMUM
ABMK OVERALL WIDTH (NON-CORE) 0.200 INCHES MAXIMUM
ADAQ BODY LENGTH 0.150 INCHES MAXIMUM
TTQY TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
CWJK CASE MATERIAL PLASTIC
CQWM NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 100.0 DC SINGLE SECTION
CWSG TERMINAL SURFACE TREATMENT SOLDER
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
DB44BY2R0C 0TCV9 A 1 C 9F 5 ZZ
DB44BY2R0D 0TCV9 A 1 C AC 6 ZZ
117620 52542 F 1 C AC 6 ZZ
DB44BY2R0C 96733 A 9 3 E TX
Manufacturers
Part SKU Cage Manufacturer Type Status
DB44BY2R0C 0TCV9 ARIZONA CAPACITORS, INC. A A
DB44BY2R0D 0TCV9 ARIZONA CAPACITORS, INC. A A
117620 52542 SYSTRON-DONNER CORP A F
DB44BY2R0C 96733 SFE TECHNOLOGIES A A
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
A X A 04/18/1 P 8532290040 0000
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DN 9B----- N
DS I
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A A P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DN SMS J 0 EA 0 U 9B----- N
DS SMS J 0 EA 0 U D
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061400 X 34450 P 72D Z 9 A H Z CONDENSERS/PARTS NOI/CAPACITORS