5910-01-227-4617 ( MIL-C-55681/4 , CDR13BG4R7EBMM , CDR13BG4R7EBMR )

NSN Information
NSN FSC NIIN Item Name INC
5910-01-227-4617 5910 012274617 CAPACITOR,FIXED,CERAMIC DIELECTR 0000
NSN Features
MRC Parameter Characteristics
CQJJ NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
ZZZK SPECIFICATION/STANDARD DATA 81349-MIL-C-55681/4 GOVERNMENT SPECIFICATION
ABJT TERMINAL LENGTH 0.015 INCHES MINIMUM
CQWM NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 500.0 DC SINGLE SECTION
TEST TEST DATA DOCUMENT 81349-MIL-C-55681 SPECIFICATION
AARG RELIABILITY INDICATOR ESTABLISHED
CQBQ CAPACITANCE VALUE PER SECTION 4.700 PICOFARADS SINGLE SECTION
CWSG TERMINAL SURFACE TREATMENT PALLADIUM AND SILVER
TTQY TERMINAL TYPE AND QUANTITY 2 BONDING PAD
ABHP OVERALL LENGTH (NON-CORE) 0.110 INCHES NOMINAL
ADAQ BODY LENGTH 0.110 INCHES NOMINAL
AARH RELIABILITY FAILURE RATE LEVEL IN PERCENT 0.0100
AAQL BODY STYLE CHIP TYPE
ADAT BODY WIDTH 0.110 INCHES NOMINAL
ABMK OVERALL WIDTH (NON-CORE) 0.110 INCHES NOMINAL
ABKW OVERALL HEIGHT 0.030 INCHES MINIMUM AND 0.102 INCHES MAXIMUM
CWJK CASE MATERIAL CERAMIC
ADAU BODY HEIGHT 0.030 INCHES MINIMUM AND 0.102 INCHES MAXIMUM
CRHD TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS -20.0/+20.0 SINGLE SECTION
AEBZ SCHEMATIC DIAGRAM DESIGNATOR NO COMMON OR GROUNDED ELECTRODE(S)
CWPK INSULATION RESISTANCE AT REFERENCE TEMP 1000000.0 MEGOHMS
PMLC PRECIOUS MATERIAL AND LOCATION TERMINAL SURFACES PALLADIUM AND TERMINAL SURFACES SILVER
CQLZ TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS 90.0 SINGLE SECTION
CQBF INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP 100000.0 MEGOHMS
CRTP TOLERANCE RANGE PER SECTION -0.10/+0.10 PICOFARADS SINGLE SECTION
PRMT PRECIOUS MATERIAL PALLADIUM AND SILVER
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
MIL-C-55681/4 81349 M 1 4 E TX
CDR13BG4R7EBMM 81349 M 1 C AC 6 ZZ
CDR13BG4R7EBMR 81349 M 2 2 E TX
Manufacturers
Part SKU Cage Manufacturer Type Status
MIL-C-55681/4 81349 MILITARY SPECIFICATIONS A M
CDR13BG4R7EBMM 81349 MILITARY SPECIFICATIONS A M
CDR13BG4R7EBMR 81349 MILITARY SPECIFICATIONS A M
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
P X A 1 03/03/1 P 8532290040 0000
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DS N I
DM Z 10B2--- M V DISCONTINUED W/O REPLACEMENT
DF N SF9EH-N F
DN 9B----- N
DA Z Q2200X- A V DISCONTINUED W/O REPLACEMENT
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A P P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DF SMS Z 0 EA 0 U SF9EH-N F
DS SMS Z 0 EA 0 U D
DA SMS V 0 EA 0 U Z Q2200X- A
DN SMS Z 0 EA 0 U 9B----- N
DM SMS V 0 EA 0 U Z 10B2--- M
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Q 2 2 00 X
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061400 X 34450 P 72D Z 9 A H Z CONDENSERS/PARTS NOI/CAPACITORS