5910-01-232-5611 ( MIL-C-55365/4 , CWR06FB156KP )

NSN Information
NSN FSC NIIN Item Name INC
5910-01-232-5611 5910 012325611 CAPACITOR,FIXED,ELECTROLYTIC 0000
NSN Features
MRC Parameter Characteristics
PRMT PRECIOUS MATERIAL (NON-CORE) GOLD
ADAU BODY HEIGHT 0.070 INCHES NOMINAL
PMLC PRECIOUS MATERIAL AND LOCATION TERMINAL SURFACES GOLD
TEST TEST DATA DOCUMENT 81349-MIL-C-55365 SPECIFICATION
ADAQ BODY LENGTH 0.220 INCHES NOMINAL
ABKW OVERALL HEIGHT (NON-CORE) 0.070 INCHES NOMINAL
ZZZK SPECIFICATION/STANDARD DATA 81349-MIL-C-55365/4 GOVERNMENT SPECIFICATION
CWSG TERMINAL SURFACE TREATMENT GOLD
CWQH DC LEAKAGE AT REFERENCE TEMP 2.000 MICROAMPERES
AARG RELIABILITY INDICATOR ESTABLISHED
ABHP OVERALL LENGTH (NON-CORE) 0.220 INCHES NOMINAL
ADAT BODY WIDTH 0.135 INCHES NOMINAL
CQBQ CAPACITANCE VALUE PER SECTION 15.000 MICROFARADS SINGLE SECTION
TTQY TERMINAL TYPE AND QUANTITY 2 BONDING PAD
CRTP TOLERANCE RANGE PER SECTION -10.00/+10.00 PERCENT SINGLE SECTION
AAQL BODY STYLE CHIP TYPE
AGAV END ITEM IDENTIFICATION 1260-01-208-6448 MAST MOUNTED SI
CWJK CASE MATERIAL CERAMIC
CQWM NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 10.0 DC SINGLE SECTION
ABMK OVERALL WIDTH (NON-CORE) 0.135 INCHES NOMINAL
AARH RELIABILITY FAILURE RATE LEVEL IN PERCENT 0.100
AEBZ SCHEMATIC DIAGRAM DESIGNATOR NO COMMON OR GROUNDED ELECTRODE(S)
CQJJ NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
AECQ ELECTRICAL POLARIZATION POLARIZED
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.190 INCHES NOMINAL
CWPM DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 8.000
CWNJ CAPACITIVE ELECTRODE MATERIAL TANTALUM
ABJT TERMINAL LENGTH 0.030 INCHES NOMINAL
CQLH DC LEAKAGE AT MAXIMUM OPERATING TEMP 20.0 MICROAMPERES
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
MIL-C-55365/4 81349 M 1 4 E TX
CWR06FB156KP 81349 M 2 2 E TX
Manufacturers
Part SKU Cage Manufacturer Type Status
MIL-C-55365/4 81349 MILITARY SPECIFICATIONS A M
CWR06FB156KP 81349 MILITARY SPECIFICATIONS A M
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
G X A 05/16/1 P 8532290040 0000
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DS N I
DA Z Q2200X- A
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A G P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DS SMS Z 0 EA 0 U D
DA SMS Z 0 EA 0 U Z Q2200X- A
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Q 2 2 00 X
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061400 X 34450 P 72D Z 9 A H Z CONDENSERS/PARTS NOI/CAPACITORS