| AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
0.290 INCHES MINIMUM AND 0.360 INCHES MAXIMUM |
| CQJJ |
NONDERATED OPERATING TEMP |
-55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
| ABHP |
OVERALL LENGTH |
0.086 INCHES MINIMUM AND 0.098 INCHES MAXIMUM |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 PRINTED CIRCUIT |
| CWPK |
INSULATION RESISTANCE AT REFERENCE TEMP |
1000.0 MEGOHM-MICROFARADS |
| CQBF |
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP |
100.0 MEGOHM-MICROFARADS |
| AARG |
RELIABILITY INDICATOR |
ESTABLISHED |
| ADAT |
BODY WIDTH |
0.240 INCHES MINIMUM AND 0.280 INCHES MAXIMUM |
| CRTP |
TOLERANCE RANGE PER SECTION |
-10.00/+10.00 PERCENT SINGLE SECTION |
| CWPM |
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT |
2.500 |
| TEST |
TEST DATA DOCUMENT |
81349-MIL-C-39014 SPECIFICATION |
| CQBQ |
CAPACITANCE VALUE PER SECTION |
3700.000 PICOFARADS SINGLE SECTION |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81349-MIL-C-39014/22 GOVERNMENT SPECIFICATION |
| ADAQ |
BODY LENGTH |
0.086 INCHES MINIMUM AND 0.098 INCHES MAXIMUM |
| ABJT |
TERMINAL LENGTH |
0.120 INCHES MINIMUM AND 0.176 INCHES MAXIMUM |
| CQFB |
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE |
-25.0/+15.0 WITH RATED VOLTAGE APPLIED SINGLE SECTION |
| AARH |
RELIABILITY FAILURE RATE LEVEL IN PERCENT |
0.100 |
| ADAU |
BODY HEIGHT |
0.121 INCHES MINIMUM AND 0.135 INCHES MAXIMUM |
| AEBZ |
SCHEMATIC DIAGRAM DESIGNATOR |
NO COMMON OR GROUNDED ELECTRODE(S) |
| ABKW |
OVERALL HEIGHT (NON-CORE) |
0.165 INCHES MAXIMUM |
| AAQL |
BODY STYLE |
DUAL INLINE |
| ABMK |
OVERALL WIDTH |
0.256 INCHES MINIMUM AND 0.312 INCHES MAXIMUM |
| CWJK |
CASE MATERIAL |
PLASTIC |
| CQWM |
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION |
100.0 DC SINGLE SECTION |