| AEBT |
TERMINAL DIAMETER |
0.032 INCHES MINIMUM AND 0.048 INCHES MAXIMUM |
| CRTP |
TOLERANCE RANGE PER SECTION |
-10.00/+75.00 PERCENT SINGLE SECTION |
| TTQY |
TERMINAL TYPE AND QUANTITY |
4 UNINSULATED WIRE LEAD |
| TEST |
TEST DATA DOCUMENT |
81349-MIL-C-39018 SPECIFICATION |
| AARG |
RELIABILITY INDICATOR |
ESTABLISHED |
| AEBZ |
SCHEMATIC DIAGRAM DESIGNATOR |
TWO COMMON TERMINALS FOR EACH ELECTRODE |
| CWJK |
CASE MATERIAL |
METAL |
| CQBQ |
CAPACITANCE VALUE PER SECTION |
2000.000 MICROFARADS SINGLE SECTION |
| CQJJ |
NONDERATED OPERATING TEMP |
-55.0 DEG CELSIUS MINIMUM AND 105.0 DEG CELSIUS MAXIMUM |
| CQWM |
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION |
25.0 DC SINGLE SECTION |
| CWNJ |
CAPACITIVE ELECTRODE MATERIAL |
ALUMINUM |
| ABKW |
OVERALL HEIGHT (NON-CORE) |
0.910 INCHES MAXIMUM |
| ABMK |
OVERALL WIDTH (NON-CORE) |
0.910 INCHES MAXIMUM |
| ADAQ |
BODY LENGTH |
2.125 INCHES MINIMUM AND 2.343 INCHES MAXIMUM |
| AAQL |
BODY STYLE |
W/O MTG FACILITIES, AXIAL TERMINALS |
| ABHP |
OVERALL LENGTH (NON-CORE) |
2.343 INCHES MAXIMUM |
| AECQ |
ELECTRICAL POLARIZATION |
POLARIZED |
| AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
0.150 INCHES MINIMUM AND 0.450 INCHES MAXIMUM |
| ABJT |
TERMINAL LENGTH |
2.250 INCHES MINIMUM AND 2.750 INCHES MAXIMUM |
| AARH |
RELIABILITY FAILURE RATE LEVEL IN PERCENT |
1.000 |
| ABPM |
BODY DIAMETER |
0.910 INCHES MAXIMUM |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81349-MIL-C-39018/7 GOVERNMENT SPECIFICATION |