| ABKW |
OVERALL HEIGHT (NON-CORE) |
0.090 INCHES NOMINAL |
| CRTP |
TOLERANCE RANGE PER SECTION |
-5.00/+5.00 PERCENT SINGLE SECTION |
| ABMK |
OVERALL WIDTH (NON-CORE) |
0.180 INCHES NOMINAL |
| ADAQ |
BODY LENGTH |
0.384 INCHES NOMINAL |
| AEBT |
TERMINAL DIAMETER |
0.016 INCHES NOMINAL |
| AARG |
RELIABILITY INDICATOR |
ESTABLISHED |
| ADAT |
BODY WIDTH |
0.180 INCHES NOMINAL |
| ABJT |
TERMINAL LENGTH |
1.000 INCHES MINIMUM |
| AAQL |
BODY STYLE |
W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE |
| ADAU |
BODY HEIGHT |
0.090 INCHES NOMINAL |
| ABHP |
OVERALL LENGTH (NON-CORE) |
0.384 INCHES NOMINAL |
| AARH |
RELIABILITY FAILURE RATE LEVEL IN PERCENT |
0.1000 |
| AEBZ |
SCHEMATIC DIAGRAM DESIGNATOR |
NO COMMON OR GROUNDED ELECTRODE(S) |
| CQJJ |
NONDERATED OPERATING TEMP |
-55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
| CWPK |
INSULATION RESISTANCE AT REFERENCE TEMP |
1000000.0 MEGOHMS |
| CQBQ |
CAPACITANCE VALUE PER SECTION |
2200.000 PICOFARADS SINGLE SECTION |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 UNINSULATED WIRE LEAD |
| CWPM |
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT |
0.3000 |
| AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
0.400 INCHES NOMINAL |
| CWJK |
CASE MATERIAL |
PLASTIC |
| CQBF |
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP |
70000.0 MEGOHMS |
| CQWM |
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION |
100.0 DC SINGLE SECTION |
| CWSG |
TERMINAL SURFACE TREATMENT |
SOLDER |