| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
4 TURRET INPUT AND 1 CONNECTOR, RECEPTACLE OUTPUT AND 2 TURRET GROUND |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
10.0 1ST RADIO INTERFERENCE |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 UNTHREADED HOLE |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
140.0 MILLIVOLTS DC 4TH RADIO INTERFERENCE |
| ADAT |
BODY WIDTH |
6.000 INCHES NOMINAL |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.196 INCHES NOMINAL |
| STYL |
STYLE DESIGNATOR |
RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE |
| AECR |
VIBRATION RESISTANCE RANGE IN HERTZ |
+10.0/+500.0 |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
12.875 INCHES NOMINAL |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 4TH RADIO INTERFERENCE |
| ABHP |
OVERALL LENGTH |
13.380 INCHES NOMINAL |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
115.0 VOLTS AC 1ST RADIO INTERFERENCE |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
| AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
10.0 2ND RADIO INTERFERENCE |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 3RD RADIO INTERFERENCE |
| AHBX |
DISTANCE BETWEEN MOUNTING SURFACE AND LOWER END |
3.500 INCHES NOMINAL |
| ADAQ |
BODY LENGTH |
8.500 INCHES NOMINAL |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
28.0 VOLTS DC 4TH RADIO INTERFERENCE |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE |
| AFGA |
OPERATING TEMP RANGE |
-55.0/+85.0 DEG CELSIUS |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 4TH RADIO INTERFERENCE |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
115.0 VOLTS AC 3RD RADIO INTERFERENCE |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
400.0 1ST RADIO INTERFERENCE |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
575.0 MILLIVOLTS AC 1ST RADIO INTERFERENCE |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
400.0 2ND RADIO INTERFERENCE |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
10.0 3RD RADIO INTERFERENCE |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
400.0 3RD RADIO INTERFERENCE |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
10.0 4TH RADIO INTERFERENCE |
| ADAU |
BODY HEIGHT |
3.000 INCHES MAXIMUM |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
575.0 MILLIVOLTS AC 2ND RADIO INTERFERENCE |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
115.0 VOLTS AC 2ND RADIO INTERFERENCE |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
575.0 MILLIVOLTS AC 3RD RADIO INTERFERENCE |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
5.562 INCHES NOMINAL |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE |
| ABKW |
OVERALL HEIGHT |
4.250 INCHES NOMINAL |
| CRDC |
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE |
500.0 VOLTS AT SEA LEVEL |