CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
125.0 VOLTS AC 2ND RADIO INTERFERENCE |
AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE |
AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
3.000 INCHES NOMINAL |
AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
3.000 INCHES NOMINAL |
ADAT |
BODY WIDTH |
4.000 INCHES NOMINAL |
AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 3RD RADIO INTERFERENCE |
STYL |
STYLE DESIGNATOR |
RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE |
AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
1.5 VOLTS AC 1ST RADIO INTERFERENCE |
ADAQ |
BODY LENGTH |
4.000 INCHES NOMINAL |
AECR |
VIBRATION RESISTANCE RANGE IN HERTZ |
+5.0/+55.0 |
AFGA |
OPERATING TEMP RANGE |
+0.0/+55.0 DEG CELSIUS |
ADAU |
BODY HEIGHT |
1.500 INCHES NOMINAL |
CQRG |
BODY MATERIAL |
METAL |
AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 THREADED STUD |
CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
4 THREADED STUD INPUT |
AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 4TH RADIO INTERFERENCE |
AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
AHCK |
FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS |
75.0 AND 100.0 AND 100.0 AND 90.0 AND 100.0 AND 90.0 |
AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
1.5 VOLTS AC 2ND RADIO INTERFERENCE |
AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
AHCJ |
FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ |
100.0 AND 200.0 AND 10.0 AND 1.0 AND 0.15 AND 400.0 |
AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 3RD RADIO INTERFERENCE |
AKEJ |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR |
UNC |
ABKW |
OVERALL HEIGHT |
0.700 INCHES NOMINAL |
AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
2.5 4TH RADIO INTERFERENCE |
AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
1.5 VOLTS AC 3RD RADIO INTERFERENCE |
AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE |
AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
0.75 1ST RADIO INTERFERENCE |
CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
4 THREADED STUD OUTPUT |
AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
0.5 VOLTS DC 4TH RADIO INTERFERENCE |
AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 4TH RADIO INTERFERENCE |
AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
400.0 1ST RADIO INTERFERENCE |
CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
30.0 VOLTS DC 4TH RADIO INTERFERENCE |
AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
AHCG |
MAXIMUM TEMP RISE |
20.0 DEG CELSIUS |
CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
125.0 VOLTS AC 1ST RADIO INTERFERENCE |
AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
0.75 2ND RADIO INTERFERENCE |
CBBL |
FEATURES PROVIDED |
NUT AND SHOCK RESISTANT |
CQJX |
NOMINAL THREAD SIZE |
0.164 INCHES |
AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
400.0 2ND RADIO INTERFERENCE |
AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
0.75 3RD RADIO INTERFERENCE |
AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
400.0 3RD RADIO INTERFERENCE |
FEAT |
SPECIAL FEATURES |
FOUR FILTERED FUNCTIONS |
CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
125.0 VOLTS AC 3RD RADIO INTERFERENCE |
AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE |
CRDC |
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE |
500.0 VOLTS AT SEA LEVEL |