| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
125.0 VOLTS AC 2ND RADIO INTERFERENCE |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE |
| ABKW |
OVERALL HEIGHT |
2.200 INCHES NOMINAL |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
3.000 INCHES NOMINAL |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
3.000 INCHES NOMINAL |
| ADAT |
BODY WIDTH |
4.000 INCHES NOMINAL |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 3RD RADIO INTERFERENCE |
| STYL |
STYLE DESIGNATOR |
RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
1.5 VOLTS AC 1ST RADIO INTERFERENCE |
| ADAQ |
BODY LENGTH |
4.000 INCHES NOMINAL |
| AECR |
VIBRATION RESISTANCE RANGE IN HERTZ |
+5.0/+55.0 |
| AFGA |
OPERATING TEMP RANGE |
+0.0/+55.0 DEG CELSIUS |
| CQRG |
BODY MATERIAL |
METAL |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 THREADED STUD |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
4 THREADED STUD INPUT |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 4TH RADIO INTERFERENCE |
| AHCJ |
FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ |
10.0 AND 100.0 AND 1.0 AND 200.0 AND 0.15 AND 400.0 |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
1.5 VOLTS AC 2ND RADIO INTERFERENCE |
| AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
| AHCK |
FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS |
90.0 AND 100.0 AND 100.0 AND 100.0 AND 75.0 AND 90.0 |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 3RD RADIO INTERFERENCE |
| AKEJ |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR |
UNC |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
1.5 VOLTS AC 3RD RADIO INTERFERENCE |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
1.5 4TH RADIO INTERFERENCE |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
0.75 1ST RADIO INTERFERENCE |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
4 THREADED STUD OUTPUT |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
0.5 VOLTS DC 4TH RADIO INTERFERENCE |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 4TH RADIO INTERFERENCE |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
400.0 1ST RADIO INTERFERENCE |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
30.0 VOLTS DC 4TH RADIO INTERFERENCE |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
| AHCG |
MAXIMUM TEMP RISE |
20.0 DEG CELSIUS |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
125.0 VOLTS AC 1ST RADIO INTERFERENCE |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
0.75 2ND RADIO INTERFERENCE |
| CBBL |
FEATURES PROVIDED |
NUT AND SHOCK RESISTANT |
| CQJX |
NOMINAL THREAD SIZE |
0.164 INCHES |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
400.0 2ND RADIO INTERFERENCE |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
0.75 3RD RADIO INTERFERENCE |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
400.0 3RD RADIO INTERFERENCE |
| FEAT |
SPECIAL FEATURES |
FOUR FILTERED FUNCTIONS |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
125.0 VOLTS AC 3RD RADIO INTERFERENCE |
| ADAU |
BODY HEIGHT |
1.000 INCHES NOMINAL |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE |
| CRDC |
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE |
500.0 VOLTS AT SEA LEVEL |