| CQDR |
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS |
2.5 2ND BAND PASS |
| CQFC |
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION |
10.00 MEGAHERTZ 3RD BAND PASS AND 30.50 MEGAHERTZ 3RD BAND PASS AND 30.94 MEGAHERTZ 3RD BAND PASS AND 80.00 MEGAHERTZ 3RD BAND PASS |
| AHAU |
INPUT IMPEDANCE PER FUNCTION W/LOAD |
50.0 OHMS 1ST BAND PASS |
| CQDR |
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS |
2.5 3RD BAND PASS |
| CRBB |
FREQUENCY BAND WIDTH PER FUNCTION |
30.50 MEGAHERTZ 2ND BAND PASS AND 30.94 MEGAHERTZ 2ND BAND PASS |
| CQJX |
NOMINAL THREAD SIZE |
0.112 INCHES |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
3.000 INCHES NOMINAL |
| CRBB |
FREQUENCY BAND WIDTH PER FUNCTION |
30.50 MEGAHERTZ 3RD BAND PASS AND 30.94 MEGAHERTZ 3RD BAND PASS |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
1.250 INCHES NOMINAL |
| STYL |
STYLE DESIGNATOR |
RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
| CQFC |
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION |
30.50 MEGAHERTZ 2ND BAND PASS AND 10.00 MEGAHERTZ 2ND BAND PASS AND 30.94 MEGAHERTZ 2ND BAND PASS AND 80.00 MEGAHERTZ 2ND BAND PASS |
| AHAU |
INPUT IMPEDANCE PER FUNCTION W/LOAD |
50.0 OHMS 2ND BAND PASS |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
6 CONNECTOR, RECEPTACLE OUTPUT |
| AHAV |
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT |
50.0 OHMS 1ST BAND PASS |
| ADAU |
BODY HEIGHT |
1.750 INCHES NOMINAL |
| CRBC |
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS |
60.0 MINIMUM 2ND BAND PASS AND 3.0 MAXIMUM 2ND BAND PASS AND 3.0 MAXIMUM 2ND BAND PASS AND 60.0 MINIMUM 2ND BAND PASS |
| AECR |
VIBRATION RESISTANCE RANGE IN HERTZ |
+10.0/+55.0 |
| CQRG |
BODY MATERIAL |
METAL |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 THREADED STUD |
| ADAQ |
BODY LENGTH |
3.500 INCHES NOMINAL |
| AHAU |
INPUT IMPEDANCE PER FUNCTION W/LOAD |
50.0 OHMS 3RD BAND PASS |
| AHAV |
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT |
50.0 OHMS 2ND BAND PASS |
| AHAJ |
REFERENCE FREQUENCY PER FUNCTION |
30.7465 HERCULES NO.5599.1 PULSES PER SECOND |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
3 CONNECTOR, RECEPTACLE INPUT |
| ABKW |
OVERALL HEIGHT |
2.125 INCHES NOMINAL |
| CRBC |
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS |
3.0 MAXIMUM 1ST BAND PASS AND 3.0 MAXIMUM 1ST BAND PASS AND 60.0 MINIMUM 1ST BAND PASS AND 60.0 MINIMUM 1ST BAND PASS |
| AKEJ |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR |
UNC |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE BLANK |
| AHAV |
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT |
50.0 OHMS 3RD BAND PASS |
| AHAJ |
REFERENCE FREQUENCY PER FUNCTION |
30.7465 HERCULES NO.5599.1 TWO PHASE TO THREE PHASE |
| AKNA |
INCLOSURE TYPE |
ENCASED |
| CQFC |
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION |
30.50 MEGAHERTZ 1ST BAND PASS AND 10.00 MEGAHERTZ 1ST BAND PASS AND 30.94 MEGAHERTZ 1ST BAND PASS AND 80.00 MEGAHERTZ 1ST BAND PASS |
| AHAJ |
REFERENCE FREQUENCY PER FUNCTION |
30.7465 HERCULES NO.5599.1 TWO PHASE TO TWO PHASE |
| CRBB |
FREQUENCY BAND WIDTH PER FUNCTION |
30.50 MEGAHERTZ 1ST BAND PASS AND 30.94 MEGAHERTZ 1ST BAND PASS |
| AFGA |
OPERATING TEMP RANGE |
+0.0/+65.0 DEG CELSIUS |
| CRBC |
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS |
3.0 MAXIMUM 3RD BAND PASS AND 3.0 MAXIMUM 3RD BAND PASS AND 60.0 MINIMUM 3RD BAND PASS AND 60.0 MINIMUM 3RD BAND PASS |
| CQDR |
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS |
2.5 1ST BAND PASS |