| ABHP |
OVERALL LENGTH |
14.000 INCHES MAXIMUM |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
3.000 INCHES NOMINAL |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
1.15 VOLTS AC 1ST RADIO INTERFERENCE |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 3RD RADIO INTERFERENCE |
| STYL |
STYLE DESIGNATOR |
RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| PKWT |
UNPACKAGED UNIT WEIGHT |
2.000 POUNDS |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
1.750 INCHES NOMINAL |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
5.0 1ST RADIO INTERFERENCE |
| ADAQ |
BODY LENGTH |
4.000 INCHES NOMINAL |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
3 TAB, SOLDER LUG OUTPUT |
| CQRG |
BODY MATERIAL |
METAL |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE |
| ADAT |
BODY WIDTH |
2.750 INCHES MAXIMUM |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
115.0 VOLTS AC 1ST RADIO INTERFERENCE |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
5.0 2ND RADIO INTERFERENCE |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 THREADED HOLE |
| AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 3RD RADIO INTERFERENCE |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
3 WIRE LEAD INPUT |
| CRST |
BODY SURFACE TREATMENT |
TIN |
| AKEJ |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR |
UNC |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
5.0 3RD RADIO INTERFERENCE |
| ABKW |
OVERALL HEIGHT |
0.280 INCHES MAXIMUM |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
1.15 VOLTS AC 3RD RADIO INTERFERENCE |
| AFGA |
OPERATING TEMP RANGE |
-55.0/+85.0 DEG CELSIUS |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
115.0 VOLTS AC 3RD RADIO INTERFERENCE |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
400.0 1ST RADIO INTERFERENCE |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
| CQJX |
NOMINAL THREAD SIZE |
0.164 INCHES |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
400.0 2ND RADIO INTERFERENCE |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
1.15 VOLTS AC 2ND RADIO INTERFERENCE |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
400.0 3RD RADIO INTERFERENCE |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
115.0 VOLTS AC 2ND RADIO INTERFERENCE |
| CRDC |
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE |
325.0 VOLTS AT SEA LEVEL |
| AHCG |
MAXIMUM TEMP RISE |
25.0 DEG CELSIUS |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE |