| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
0.1 5TH RADIO INTERFERENCE |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
6 TAB, SOLDER LUG OUTPUT |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
0.1 6TH RADIO INTERFERENCE |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE |
| ADAQ |
BODY LENGTH |
5.250 INCHES NOMINAL |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
1.250 INCHES NOMINAL |
| AFGA |
OPERATING TEMP RANGE |
-32.0/+150.0 DEG FAHRENHEIT |
| AHBP |
INPUT TERMINAL IDENTIFICATION |
G502-8-P-001 |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 3RD RADIO INTERFERENCE |
| STYL |
STYLE DESIGNATOR |
RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
115.0 VOLTS AC 6TH RADIO INTERFERENCE |
| CQJX |
NOMINAL THREAD SIZE |
0.190 INCHES |
| ADAU |
BODY HEIGHT |
4.000 INCHES NOMINAL |
| CQRG |
BODY MATERIAL |
METAL |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 4TH RADIO INTERFERENCE |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
60.0 1ST RADIO INTERFERENCE |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
115.0 VOLTS AC 1ST RADIO INTERFERENCE |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
60.0 2ND RADIO INTERFERENCE |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
4 TAB, SOLDER LUG GROUND |
| AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
60.0 3RD RADIO INTERFERENCE |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 5TH RADIO INTERFERENCE |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
60.0 4TH RADIO INTERFERENCE |
| AHBN |
INPUT TERMINAL MANUFACTURER CODE |
98438 |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 3RD RADIO INTERFERENCE |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
60.0 5TH RADIO INTERFERENCE |
| CRST |
BODY SURFACE TREATMENT |
TIN |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
1 CONNECTOR, RECEPTACLE INPUT |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
60.0 6TH RADIO INTERFERENCE |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE |
| AKEJ |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR |
UNF |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
115.0 VOLTS AC 5TH RADIO INTERFERENCE |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
4.500 INCHES NOMINAL |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
115.0 VOLTS AC 4TH RADIO INTERFERENCE |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 4TH RADIO INTERFERENCE |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
115.0 VOLTS AC 3RD RADIO INTERFERENCE |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
8.0 1ST RADIO INTERFERENCE |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 THREADED STUD |
| ADAT |
BODY WIDTH |
2.000 INCHES NOMINAL |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 5TH RADIO INTERFERENCE |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
115.0 VOLTS AC 2ND RADIO INTERFERENCE |
| FEAT |
SPECIAL FEATURES |
10 FUNCTIONS |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
8.0 2ND RADIO INTERFERENCE |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
0.1 3RD RADIO INTERFERENCE |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
0.1 4TH RADIO INTERFERENCE |