| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
125.0 VOLTS AC 2ND RADIO INTERFERENCE |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 6TH RADIO INTERFERENCE |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
2.0 5TH RADIO INTERFERENCE |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
1.0 3RD RADIO INTERFERENCE |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
2.0 6TH RADIO INTERFERENCE |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 3RD RADIO INTERFERENCE |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
100.0 VOLTS DC 3RD RADIO INTERFERENCE |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
100.0 VOLTS DC 4TH RADIO INTERFERENCE |
| STYL |
STYLE DESIGNATOR |
RECTANGULAR TERMINAL/TERMINALS ON THREE SURFACES |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
0.3 VOLTS DC 3RD RADIO INTERFERENCE |
| CBBL |
FEATURES PROVIDED |
CORROSION RESISTANT AND SHOCK RESISTANT |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
1.0 4TH RADIO INTERFERENCE |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE |
| AFGA |
OPERATING TEMP RANGE |
-65.0/+125.0 DEG CELSIUS |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 4TH RADIO INTERFERENCE |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
0.6 VOLTS AC 1ST RADIO INTERFERENCE |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
2.0 1ST RADIO INTERFERENCE |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
0.3 VOLTS DC 4TH RADIO INTERFERENCE |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
0.3 VOLTS DC 5TH RADIO INTERFERENCE |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
0.3 VOLTS DC 6TH RADIO INTERFERENCE |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
0.6 VOLTS AC 2ND RADIO INTERFERENCE |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 THREADED HOLE |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
8 TAB, SOLDER LUG OUTPUT AND 1 RECTANGULAR FLANGE GROUND |
| AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
| ADAT |
BODY WIDTH |
3.156 INCHES NOMINAL |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 5TH RADIO INTERFERENCE |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 3RD RADIO INTERFERENCE |
| AECR |
VIBRATION RESISTANCE RANGE IN HERTZ |
+5.0/+1500.0 |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
1 CONNECTOR, RECEPTACLE INPUT |
| CQRG |
BODY MATERIAL |
ALUMINUM |
| AKEJ |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR |
UNC |
| ADAQ |
BODY LENGTH |
5.000 INCHES NOMINAL |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 6TH RADIO INTERFERENCE |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
28.0 VOLTS DC 5TH RADIO INTERFERENCE |
| ADAU |
BODY HEIGHT |
1.938 INCHES NOMINAL |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
28.0 VOLTS DC 6TH RADIO INTERFERENCE |
| AHBN |
INPUT TERMINAL MANUFACTURER CODE |
26916 |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 4TH RADIO INTERFERENCE |
| CQDZ |
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE |
250.0 VOLTS AT SEA LEVEL |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
400.0 1ST RADIO INTERFERENCE |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
| AHBP |
INPUT TERMINAL IDENTIFICATION |
SMA-RECEPTACLE |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
2.0 2ND RADIO INTERFERENCE |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
1.562 INCHES NOMINAL |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
1.562 INCHES NOMINAL |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
125.0 VOLTS AC 1ST RADIO INTERFERENCE |
| CQJX |
NOMINAL THREAD SIZE |
0.164 INCHES |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
400.0 2ND RADIO INTERFERENCE |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 5TH RADIO INTERFERENCE |
| ABHP |
OVERALL LENGTH |
5.750 INCHES NOMINAL |
| CRDC |
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE |
200.0 VOLTS AT SEA LEVEL |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
13 RECTANGULAR FLANGE OUTPUT |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE |
| FEAT |
SPECIAL FEATURES |
TWENTY-ONE FILTERED FUNCTIONS |
| ABKW |
OVERALL HEIGHT |
2.938 INCHES NOMINAL |