| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
3 THREADED STUD OUTPUT |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 UNTHREADED HOLE |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
28.000 INCHES NOMINAL |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE |
| ABMK |
OVERALL WIDTH |
27.875 INCHES NOMINAL |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
26.375 INCHES NOMINAL |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 3RD RADIO INTERFERENCE |
| STYL |
STYLE DESIGNATOR |
RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| CQDZ |
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE |
500.0 VOLTS AT SEA LEVEL |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
2.0 VOLTS AC 1ST RADIO INTERFERENCE |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
100.0 1ST RADIO INTERFERENCE |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
60.0 1ST RADIO INTERFERENCE |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.375 INCHES NOMINAL |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
100.0 2ND RADIO INTERFERENCE |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
100.0 3RD RADIO INTERFERENCE |
| AAFZ |
BODY MATERIAL |
STEEL |
| ADAQ |
BODY LENGTH |
39.875 INCHES NOMINAL |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
60.0 2ND RADIO INTERFERENCE |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
3 THREADED STUD INPUT |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
60.0 3RD RADIO INTERFERENCE |
| ADAT |
BODY WIDTH |
24.875 INCHES NOMINAL |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 3RD RADIO INTERFERENCE |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
2.0 VOLTS AC 2ND RADIO INTERFERENCE |
| ABHP |
OVERALL LENGTH |
39.875 INCHES NOMINAL |
| ABKW |
OVERALL HEIGHT |
7.500 INCHES NOMINAL |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE |
| AFGA |
OPERATING TEMP RANGE |
-30.0/+85.0 DEG CELSIUS |
| FEAT |
SPECIAL FEATURES |
TERMINALS LOCATED ON OPPOSITE ENDS OF FILTER |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
250.0 VOLTS AC 3RD RADIO INTERFERENCE |
| AKNA |
INCLOSURE TYPE |
ENCASED |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
2.0 VOLTS AC 3RD RADIO INTERFERENCE |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
250.0 VOLTS AC 2ND RADIO INTERFERENCE |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
250.0 VOLTS AC 1ST RADIO INTERFERENCE |