5915-01-025-9192 ( 792306-PIECE 154 , GF 55622 , GF 55622 , 905556-1 , 10 B 611 )

NSN Information
NSN FSC NIIN Item Name INC
5915-01-025-9192 5915 010259192 FILTER,RADIO FREQUENCY INTERFERE 0076
NSN Features
MRC Parameter Characteristics
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 4.0 1ST RADIO INTERFERENCE
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 150.0 VOLTS DC 4TH RADIO INTERFERENCE
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 150.0 VOLTS DC 5TH RADIO INTERFERENCE
ABKW OVERALL HEIGHT 2.000 INCHES MAXIMUM
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 4.0 2ND RADIO INTERFERENCE
AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 3RD RADIO INTERFERENCE
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 4.0 3RD RADIO INTERFERENCE
STYL STYLE DESIGNATOR RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE
AHCG MAXIMUM TEMP RISE 30.0 DEG CELSIUS
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 1.5 VOLTS DC 4TH RADIO INTERFERENCE
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 1.5 VOLTS DC 5TH RADIO INTERFERENCE
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 2.000 INCHES NOMINAL
CQDW FUNCTIONAL TERMINAL TYPE AND QUANTITY 5 THREADED STUD INPUT
CQRG BODY MATERIAL METAL
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 2ND RADIO INTERFERENCE
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 8.625 INCHES NOMINAL
AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 4TH RADIO INTERFERENCE
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 60.0 1ST RADIO INTERFERENCE
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 115.0 VOLTS AC 1ST RADIO INTERFERENCE
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.218 INCHES MINIMUM AND 0.224 INCHES MAXIMUM
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE
CQDW FUNCTIONAL TERMINAL TYPE AND QUANTITY 5 THREADED STUD OUTPUT
ABHP OVERALL LENGTH 10.100 INCHES MAXIMUM
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 60.0 2ND RADIO INTERFERENCE
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 60.0 3RD RADIO INTERFERENCE
AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 5TH RADIO INTERFERENCE
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 3RD RADIO INTERFERENCE
ADAT BODY WIDTH 2.720 INCHES MINIMUM AND 2.780 INCHES MAXIMUM
AFGA OPERATING TEMP RANGE -55.0/+78.0 DEG CELSIUS
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 1.25 VOLTS AC 1ST RADIO INTERFERENCE
AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 4TH RADIO INTERFERENCE
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 115.0 VOLTS AC 3RD RADIO INTERFERENCE
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
AKNA INCLOSURE TYPE ENCASED
CQDW FUNCTIONAL TERMINAL TYPE AND QUANTITY 2 THREADED STUD GROUND
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 5.75 4TH RADIO INTERFERENCE
ADAQ BODY LENGTH 6.500 INCHES MAXIMUM
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 5TH RADIO INTERFERENCE
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 115.0 VOLTS AC 2ND RADIO INTERFERENCE
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 5.75 5TH RADIO INTERFERENCE
AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 2ND RADIO INTERFERENCE
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 1.25 VOLTS AC 3RD RADIO INTERFERENCE
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 1.25 VOLTS AC 2ND RADIO INTERFERENCE
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
792306-PIECE 154 06481 A 2 5 1 TX
GF 55622 07294 A 9 5 5 TX
GF 55622 13050 A 9 5 3 TX
905556-1 06481 A 2 3 1 TX
10 B 611 13058 A 2 5 3 TX
Manufacturers
Part SKU Cage Manufacturer Type Status
792306-PIECE 154 06481 NORTHROP GRUMMAN GUIDANCE AND A A
GF 55622 07294 GENISCO FILTER CORP. A A
GF 55622 13050 SPECTRUM CONTROL INC. A A
905556-1 06481 NORTHROP GRUMMAN GUIDANCE AND A A
10 B 611 13058 SORA POWER INC. A A
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
U X A 08/12/1 P 8527995030 0076
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DN 9B----- N
DS I
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A U P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DN SMS J 0 EA 0 U 9B----- N
DS SMS J 0 EA 0 U D
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061400 X 34450 P 72D Z 9 A H Z CONDENSERS/PARTS NOI/CAPACITORS