5915-01-028-0891 ( 2887715-1 , 2887715-1 , 2887715-1 , A10006A )

NSN Information
NSN FSC NIIN Item Name INC
5915-01-028-0891 5915 010280891 FILTER,RADIO FREQUENCY INTERFERE 0076
NSN Features
MRC Parameter Characteristics
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 1.0 2ND RADIO INTERFERENCE
CQDW FUNCTIONAL TERMINAL TYPE AND QUANTITY 3 THREADED STUD OUTPUT
ADAQ BODY LENGTH 1.830 INCHES MAXIMUM
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE
AECR VIBRATION RESISTANCE RANGE IN HERTZ +10.0/+2000.0
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 1.15 VOLTS AC 1ST RADIO INTERFERENCE
AFSV AVERAGE LIFE RATING IN HOURS 20000.0
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 1.0 3RD RADIO INTERFERENCE
ADAT BODY WIDTH 1.830 INCHES MAXIMUM
AFGA OPERATING TEMP RANGE -28.0/+75.0 DEG CELSIUS
AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 TERMINAL
AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 3RD RADIO INTERFERENCE
STYL STYLE DESIGNATOR RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
CQDW FUNCTIONAL TERMINAL TYPE AND QUANTITY 1 THREADED STUD GROUND
ABKW OVERALL HEIGHT 4.080 INCHES MAXIMUM
AHBP INPUT TERMINAL IDENTIFICATION BFH-16-10P-002
AHBN INPUT TERMINAL MANUFACTURER CODE 71468
CQRG BODY MATERIAL METAL
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 2ND RADIO INTERFERENCE
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 115.0 VOLTS AC 1ST RADIO INTERFERENCE
ADAU BODY HEIGHT 2.280 INCHES MAXIMUM
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 3RD RADIO INTERFERENCE
CQDW FUNCTIONAL TERMINAL TYPE AND QUANTITY 1 CONNECTOR, RECEPTACLE INPUT
AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 1.15 VOLTS AC 3RD RADIO INTERFERENCE
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 115.0 VOLTS AC 3RD RADIO INTERFERENCE
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 1ST RADIO INTERFERENCE
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 1.0 1ST RADIO INTERFERENCE
AKNA INCLOSURE TYPE ENCASED
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 2ND RADIO INTERFERENCE
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 1.15 VOLTS AC 2ND RADIO INTERFERENCE
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 3RD RADIO INTERFERENCE
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 115.0 VOLTS AC 2ND RADIO INTERFERENCE
AHCG MAXIMUM TEMP RISE 25.0 DEG CELSIUS
AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 2ND RADIO INTERFERENCE
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
2887715-1 49956 A 9 5 5 TX
2887715-1 3B150 A 2 5 5 TX
2887715-1 10001 A 2 3 1 TX
A10006A 23939 A 2 5 5 TX
Manufacturers
Part SKU Cage Manufacturer Type Status
2887715-1 49956 RAYTHEON COMPANY A A
2887715-1 3B150 RAYTHEON TECHNICAL SERVICES COMP A A
2887715-1 10001 NAVAIR AND NAVSEA MANAGED A A
A10006A 23939 THE CAPTOR CORPORATION A A
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
U X A 09/24/1 P 8527995030 0076
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DS I
DN 9B----- N
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A U P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DS SMS Z 0 EA 0 U D
DN SMS Z 0 EA 0 U 9B----- N
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061400 X 34450 P 72D Z 9 A H Z CONDENSERS/PARTS NOI/CAPACITORS