5915-01-176-3059 ( 08P228129 , 51-750-311 , 08P228129-01 , 51-750-311 )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5915-01-176-3059 | 5915 | 011763059 | FILTER,RADIO FREQUENCY INTERFERE | 0076 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| AFGA | OPERATING TEMP RANGE | -55.0/+125.0 DEG CELSIUS |
| CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 120.0 VOLTS AT SEA LEVEL |
| AECR | VIBRATION RESISTANCE RANGE IN HERTZ | +10.0/+2000.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS BLANK |
| CBBL | FEATURES PROVIDED | SHOCK RESISTANT |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 WIRE LEAD INPUT |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 0.1 VOLTS DC BLANK |
| ADAQ | BODY LENGTH | 0.279 INCHES NOMINAL |
| CQRG | BODY MATERIAL | METAL |
| ADAR | BODY OUTSIDE DIAMETER | 0.203 INCHES MAXIMUM |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TURRET OUTPUT |
| ABHP | OVERALL LENGTH | 0.765 INCHES MAXIMUM |
| CRST | BODY SURFACE TREATMENT | TIN |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE BLANK |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 100.0 VOLTS 23RD BAND SUPPRESSION NOT SPECIFIED |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS BLANK |
| STYL | STYLE DESIGNATOR | ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| AKNA | INCLOSURE TYPE | ENCASED |
| PKWT | UNPACKAGED UNIT WEIGHT | 0.7 GRAMS |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 BLANK |
| AHCG | MAXIMUM TEMP RISE | 25.0 DEG CELSIUS |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| 08P228129 | 98738 | E | 2 | 5 | A | TX | |
| 51-750-311 | 0LSP2 | A | 2 | 3 | 5 | ZZ | |
| 08P228129-01 | 98738 | E | 2 | 3 | 6 | TX | |
| 51-750-311 | 33095 | A | 9 | 5 | 6 | TX |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| 08P228129 | 98738 | HERLEY CHICAGO | A | E |
| 51-750-311 | 0LSP2 | SPECTRUM CONTROL INC. | F | A |
| 08P228129-01 | 98738 | HERLEY CHICAGO | A | E |
| 51-750-311 | 33095 | SPECTRUM CONTROL, INC. | A | A |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| A | X | A | 04/11/1 | P | 8527995030 | 0076 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DN | 9B----- | N | |||
| DS | I |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| A | A | P | X |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DN | SMS | Z | 0 | EA | 0 | U | 9B----- | N | |
| DS | SMS | Z | 0 | EA | 0 | U | D |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 061400 | X | 34450 | P | 72D | Z | 9 | A | H | Z | CONDENSERS/PARTS NOI/CAPACITORS |