| AHAJ |
REFERENCE FREQUENCY PER FUNCTION |
620.0 HERCULES NO.5599.1 PULSES PER SECOND |
| CRBC |
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS |
5.0 MAXIMUM 1ST BAND PASS AND 40.0 MINIMUM 1ST BAND PASS AND 5.0 MAXIMUM 1ST BAND PASS AND 40.0 MINIMUM 1ST BAND PASS |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 3RD BAND PASS |
| AHAJ |
REFERENCE FREQUENCY PER FUNCTION |
640.0 HERCULES NO.5599.1 HERTZ |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 UNTHREADED HOLE |
| AFSV |
AVERAGE LIFE RATING IN HOURS |
10000.0 |
| CRBN |
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION |
639.0 HERCULES NO.5599.1 HERTZ AND 641.0 HERCULES NO.5599.1 HERTZ |
| AHAJ |
REFERENCE FREQUENCY PER FUNCTION |
680.0 HERCULES NO.5599.1 TWO PHASE TO THREE PHASE |
| PRMT |
PRECIOUS MATERIAL |
SILVER |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 4TH BAND PASS |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 2ND BAND PASS |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
4 PIN INPUT |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.120 INCHES NOMINAL |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 1ST BAND PASS |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
1.520 INCHES NOMINAL |
| AFGA |
OPERATING TEMP RANGE |
-46.0/+75.0 DEG CELSIUS |
| STYL |
STYLE DESIGNATOR |
RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 4TH BAND PASS |
| CRBB |
FREQUENCY BAND WIDTH PER FUNCTION |
639.00 MEGAHERTZ 4TH BAND PASS AND 641.00 MEGAHERTZ 4TH BAND PASS |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
4 PIN OUTPUT |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
2.000 INCHES NOMINAL |
| AHBZ |
VOLTAGE STANDING WAVE RATIO PER FUNCTION |
1.5 1ST BAND PASS |
| CRBC |
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS |
5.0 MAXIMUM 2ND BAND PASS AND 5.0 MAXIMUM 2ND BAND PASS AND 40.0 MINIMUM 2ND BAND PASS AND 40.0 MINIMUM 2ND BAND PASS |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 3RD BAND PASS |
| ADAT |
BODY WIDTH |
3.500 INCHES NOMINAL |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 1ST BAND PASS |
| CRBN |
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION |
619.0 HERCULES NO.5599.1 PULSES PER SECOND AND 621.0 HERCULES NO.5599.1 PULSES PER SECOND |
| AHBZ |
VOLTAGE STANDING WAVE RATIO PER FUNCTION |
1.5 2ND BAND PASS |
| CRBB |
FREQUENCY BAND WIDTH PER FUNCTION |
619.00 MEGAHERTZ 1ST BAND PASS AND 621.00 MEGAHERTZ 1ST BAND PASS |
| CRBN |
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION |
659.0 HERCULES NO.5599.1 TWO PHASE TO TWO PHASE AND 661.0 HERCULES NO.5599.1 TWO PHASE TO TWO PHASE |
| CRBB |
FREQUENCY BAND WIDTH PER FUNCTION |
659.00 MEGAHERTZ 2ND BAND PASS AND 661.00 MEGAHERTZ 2ND BAND PASS |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 2ND BAND PASS |
| CQFC |
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION |
619.00 MEGAHERTZ 1ST BAND PASS AND 600.00 MEGAHERTZ 1ST BAND PASS AND 621.00 MEGAHERTZ 1ST BAND PASS AND 640.00 MEGAHERTZ 1ST BAND PASS |
| CRBC |
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS |
5.0 MAXIMUM 3RD BAND PASS AND 5.0 MAXIMUM 3RD BAND PASS AND 40.0 MINIMUM 3RD BAND PASS AND 40.0 MINIMUM 3RD BAND PASS |
| ABMK |
OVERALL WIDTH |
3.780 INCHES NOMINAL |
| ABKW |
OVERALL HEIGHT |
0.380 INCHES NOMINAL |
| CQRG |
BODY MATERIAL |
ALUMINUM |
| ADAQ |
BODY LENGTH |
1.320 INCHES NOMINAL |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 4TH BAND PASS |
| CRBN |
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION |
679.0 HERCULES NO.5599.1 TWO PHASE TO THREE PHASE AND 681.0 HERCULES NO.5599.1 TWO PHASE TO THREE PHASE |
| CRBC |
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS |
5.0 MAXIMUM 4TH BAND PASS AND 5.0 MAXIMUM 4TH BAND PASS AND 40.0 MINIMUM 4TH BAND PASS AND 40.0 MINIMUM 4TH BAND PASS |
| AHBZ |
VOLTAGE STANDING WAVE RATIO PER FUNCTION |
1.5 3RD BAND PASS |
| PMLC |
PRECIOUS MATERIAL AND LOCATION |
TERMINAL SURFACES SILVER |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 2ND BAND PASS |
| AKNA |
INCLOSURE TYPE |
ENCASED |
| AHBZ |
VOLTAGE STANDING WAVE RATIO PER FUNCTION |
1.5 4TH BAND PASS |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 3RD BAND PASS |
| CQFC |
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION |
660.00 MEGAHERTZ 3RD BAND PASS AND 679.00 MEGAHERTZ 3RD BAND PASS AND 681.00 MEGAHERTZ 3RD BAND PASS AND 700.00 MEGAHERTZ 3RD BAND PASS |
| CQDR |
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS |
5.0 1ST BAND PASS |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 1ST BAND PASS |
| CQFC |
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION |
659.00 MEGAHERTZ 2ND BAND PASS AND 640.00 MEGAHERTZ 2ND BAND PASS AND 661.00 MEGAHERTZ 2ND BAND PASS AND 680.00 MEGAHERTZ 2ND BAND PASS |
| AHAJ |
REFERENCE FREQUENCY PER FUNCTION |
660.0 HERCULES NO.5599.1 TWO PHASE TO TWO PHASE |
| ABHP |
OVERALL LENGTH |
1.720 INCHES NOMINAL |
| CRBB |
FREQUENCY BAND WIDTH PER FUNCTION |
679.00 MEGAHERTZ 3RD BAND PASS AND 681.00 MEGAHERTZ 3RD BAND PASS |
| CQDR |
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS |
5.0 2ND BAND PASS |
| CQDR |
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS |
5.0 3RD BAND PASS |
| CQFC |
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION |
641.00 MEGAHERTZ 4TH BAND PASS AND 620.00 MEGAHERTZ 4TH BAND PASS AND 639.00 MEGAHERTZ 4TH BAND PASS AND 660.00 MEGAHERTZ 4TH BAND PASS |
| CQDR |
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS |
5.0 4TH BAND PASS |