5915-01-310-1929 ( HP4-10 )

NSN Information
NSN FSC NIIN Item Name INC
5915-01-310-1929 5915 013101929 FILTER,RADIO FREQUENCY INTERFERE 0076
NSN Features
MRC Parameter Characteristics
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 10.0 1ST RADIO INTERFERENCE
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE
CQDW FUNCTIONAL TERMINAL TYPE AND QUANTITY 2 THREADED STUD OUTPUT
STYL STYLE DESIGNATOR RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
CQDW FUNCTIONAL TERMINAL TYPE AND QUANTITY 1 THREADED STUD GROUND
ADAU BODY HEIGHT 1.500 INCHES NOMINAL
CQRG BODY MATERIAL METAL
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 2ND RADIO INTERFERENCE
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.940 INCHES NOMINAL
FEAT SPECIAL FEATURES CONSISTS OF TWO FILTERED FUNCTIONS
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 60.0 1ST RADIO INTERFERENCE
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 60.0 2ND RADIO INTERFERENCE
CRDC MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE 2.25 KILOVOLTS AT SEA LEVEL
ADAQ BODY LENGTH 2.500 INCHES NOMINAL
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.188 INCHES NOMINAL
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 10.0 2ND RADIO INTERFERENCE
AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE
ABHP OVERALL LENGTH 3.175 INCHES NOMINAL
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
AKNA INCLOSURE TYPE ENCASED
ADAT BODY WIDTH 2.000 INCHES NOMINAL
CQDW FUNCTIONAL TERMINAL TYPE AND QUANTITY 2 THREADED STUD INPUT
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 250.0 VOLTS AC 2ND RADIO INTERFERENCE
AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 2ND RADIO INTERFERENCE
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 250.0 VOLTS AC 1ST RADIO INTERFERENCE
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
HP4-10 23880 A 2 3 E TX
Manufacturers
Part SKU Cage Manufacturer Type Status
HP4-10 23880 STANFORD APPLIED ENGINEERING INC A A
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
A X A 10/31/1 P 8527995030 0076
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DF N SF9EH-N F
DN 9B----- N
DS N I
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A A P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DN SMS Z 0 EA 0 U 9B----- N
DF SMS Z 0 EA 0 U SF9EH-N F
DS SMS Z 0 EA 0 U D
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC