| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.115 INCHES MINIMUM AND 0.125 INCHES MAXIMUM |
| AFGA |
OPERATING TEMP RANGE |
-55.0/+125.0 DEG CELSIUS |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 3RD RADIO INTERFERENCE |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
125.0 VOLTS AC 1ST RADIO INTERFERENCE AND 200.0 VOLTS DC 1ST RADIO INTERFERENCE |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE |
| FEAT |
SPECIAL FEATURES |
50 FILTERED PIN CONNECTOR |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
50 FRICTION W/GROUNDING STRAP AND PIN OUTPUT |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
125.0 VOLTS AC 2ND RADIO INTERFERENCE AND 200.0 VOLTS DC 2ND RADIO INTERFERENCE |
| STYL |
STYLE DESIGNATOR |
FILTER CONNECTOR |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
3.0 1ST RADIO INTERFERENCE |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 3RD RADIO INTERFERENCE |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
50.0 VOLTS AC 3RD RADIO INTERFERENCE AND 100.0 VOLTS DC 3RD RADIO INTERFERENCE |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
1 CONNECTOR, PLUG INPUT |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE |
| ABKW |
OVERALL HEIGHT |
0.965 INCHES MAXIMUM |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
400.0 1ST RADIO INTERFERENCE |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
| ABMK |
OVERALL WIDTH |
0.590 INCHES MINIMUM AND 0.720 INCHES MAXIMUM |
| AKNA |
INCLOSURE TYPE |
ENCASED |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
3.0 2ND RADIO INTERFERENCE |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
400.0 2ND RADIO INTERFERENCE |
| AECR |
VIBRATION RESISTANCE RANGE IN HERTZ |
+20.0/+2000.0 |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
400.0 3RD RADIO INTERFERENCE |
| ABHP |
OVERALL LENGTH |
2.620 INCHES MINIMUM AND 2.658 INCHES MAXIMUM |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
3.0 3RD RADIO INTERFERENCE |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.401 INCHES MINIMUM AND 2.411 INCHES MAXIMUM |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 UNTHREADED HOLE |