| AFSV |
AVERAGE LIFE RATING IN HOURS |
1000.0 |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
460.0 1ST RADIO INTERFERENCE |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
460.0 2ND RADIO INTERFERENCE |
| AFGA |
OPERATING TEMP RANGE |
-28.0/+65.0 DEG CELSIUS |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
2 TAB, SOLDER LUG OUTPUT |
| ADAU |
BODY HEIGHT |
3.000 INCHES NOMINAL |
| AGAV |
END ITEM IDENTIFICATION |
TACTICAL AIR OPERATIONS MODULE AN/TYQ-23(V)1 |
| STYL |
STYLE DESIGNATOR |
RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| ABHP |
OVERALL LENGTH |
6.312 INCHES NOMINAL |
| CQRG |
BODY MATERIAL |
METAL |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE |
| ADAT |
BODY WIDTH |
1.250 INCHES NOMINAL |
| ADAQ |
BODY LENGTH |
6.000 INCHES NOMINAL |
| CBBL |
FEATURES PROVIDED |
FUNGUS RESISTANT AND SHOCK RESISTANT |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 THREADED HOLE |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
150.0 VOLTS AC 1ST RADIO INTERFERENCE |
| AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
2.625 INCHES NOMINAL |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
3.0 VOLTS AC 1ST RADIO INTERFERENCE |
| CRST |
BODY SURFACE TREATMENT |
TIN |
| AKEJ |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR |
UNC |
| AHCK |
FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS |
75.0 AND 20.0 AND 90.0 AND 90.0 AND 90.0 AND 90.0 |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
3.0 VOLTS AC 2ND RADIO INTERFERENCE |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
1 TAB, SOLDER LUG GROUND |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
1 CONNECTOR, PLUG INPUT |
| FEAT |
SPECIAL FEATURES |
TWO FILTERED FUNCTIONS |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE |
| CRDC |
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE |
300.0 VOLTS AT SEA LEVEL |
| AHCJ |
FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ |
0.0 AND 0.1 AND 1.0 AND 10.0 AND 100.0 AND 1000.0 |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
4.500 INCHES NOMINAL |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
| AHBP |
INPUT TERMINAL IDENTIFICATION |
SMA-RECEPTACLE |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
6.0 1ST RADIO INTERFERENCE |
| CQJX |
NOMINAL THREAD SIZE |
0.164 INCHES |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
150.0 VOLTS AC 2ND RADIO INTERFERENCE |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
6.0 2ND RADIO INTERFERENCE |
| AHCH |
AVERAGE POWER RATING PER FUNCTION |
1.5 WATTS 1ST RADIO INTERFERENCE |
| PKWT |
UNPACKAGED UNIT WEIGHT |
3.500 POUNDS |
| AHCG |
MAXIMUM TEMP RISE |
25.0 DEG CELSIUS |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE |
| AHBN |
INPUT TERMINAL MANUFACTURER CODE |
13973 |
| AHCH |
AVERAGE POWER RATING PER FUNCTION |
1.5 WATTS 2ND RADIO INTERFERENCE |