5915-01-340-9967 ( 842920-1 , 842920-1 )

NSN Information
NSN FSC NIIN Item Name INC
5915-01-340-9967 5915 013409967 FILTER,RADIO FREQUENCY INTERFERE 0076
NSN Features
MRC Parameter Characteristics
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 2.5 VOLTS AC 6TH RADIO INTERFERENCE AND 2.5 VOLTS AC 5TH RADIO INTERFERENCE AND 2.5 VOLTS AC 4TH RADIO INTERFERENCE AND 2.5 VOLTS AC 3RD RADIO INTERFERENCE AND 2.5 VOLTS AC 2ND RADIO INTERFERENCE AND 2.5 VOLTS AC 1ST RADIO INTERFERENCE AND 8.0 VOLTS DC 2ND RADIO INTERFERENCE
AFGA OPERATING TEMP RANGE -55.0/+125.0 DEG CELSIUS
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 6TH RADIO INTERFERENCE
CRDC MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE 1.2 KILOVOLTS AT SEA LEVEL
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE
PRMT PRECIOUS MATERIAL GOLD
AHBS OUTPUT TERMINAL MANUFACTURER CODE 00779
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.120 INCHES NOMINAL
AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 3RD RADIO INTERFERENCE
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 250.0 VOLTS AC 1ST RADIO INTERFERENCE AND 250.0 VOLTS AC 2ND RADIO INTERFERENCE AND 250.0 VOLTS AC 3RD RADIO INTERFERENCE AND 250.0 VOLTS AC 4TH RADIO INTERFERENCE AND 250.0 VOLTS AC 6TH RADIO INTERFERENCE AND 250.0 VOLTS AC 5TH RADIO INTERFERENCE AND 800.0 VOLTS DC 2ND RADIO INTERFERENCE
ABHP OVERALL LENGTH 1.198 INCHES MINIMUM AND 1.228 INCHES MAXIMUM
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 5.0 1ST RADIO INTERFERENCE
CQDW FUNCTIONAL TERMINAL TYPE AND QUANTITY 9 FRICTION W/GROUNDING STRAP AND PIN INPUT-OUTPUT
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 0.984 INCHES NOMINAL
CQRG BODY MATERIAL METAL
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 2ND RADIO INTERFERENCE
AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 4TH RADIO INTERFERENCE
AHBP INPUT TERMINAL IDENTIFICATION SMA-CONNECTOR
FEAT SPECIAL FEATURES NINE FILTERED FUNCTIONS
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE
PMLC PRECIOUS MATERIAL AND LOCATION CONTACT SURFACES GOLD
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 800.0 VOLTS DC 1ST RADIO INTERFERENCE
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 5.0 2ND RADIO INTERFERENCE
AKNA INCLOSURE TYPE HERMETICALLY SEALED
STYL STYLE DESIGNATOR FILTER CONNECTOR
ABKW OVERALL HEIGHT 0.930 INCHES MAXIMUM
AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 5TH RADIO INTERFERENCE
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 3RD RADIO INTERFERENCE
CRST BODY SURFACE TREATMENT TIN
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 800.0 VOLTS DC 3RD RADIO INTERFERENCE
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 5.0 3RD RADIO INTERFERENCE
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 800.0 VOLTS DC 4TH RADIO INTERFERENCE
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 5.0 4TH RADIO INTERFERENCE
ABMK OVERALL WIDTH 0.485 INCHES MINIMUM AND 0.515 INCHES MAXIMUM
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 800.0 VOLTS DC 5TH RADIO INTERFERENCE
AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 6TH RADIO INTERFERENCE
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 5.0 5TH RADIO INTERFERENCE
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 800.0 VOLTS DC 6TH RADIO INTERFERENCE
AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 5.0 6TH RADIO INTERFERENCE
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 4TH RADIO INTERFERENCE
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 1ST RADIO INTERFERENCE
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 8.0 VOLTS DC 1ST RADIO INTERFERENCE
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 2ND RADIO INTERFERENCE
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 3RD RADIO INTERFERENCE
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 8.0 VOLTS DC 3RD RADIO INTERFERENCE
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 4TH RADIO INTERFERENCE
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 8.0 VOLTS DC 4TH RADIO INTERFERENCE
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 5TH RADIO INTERFERENCE
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 5TH RADIO INTERFERENCE
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 8.0 VOLTS DC 5TH RADIO INTERFERENCE
AHBT OUTPUT TERMINAL IDENTIFICATION SMA-RECEPTACLE
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 6TH RADIO INTERFERENCE
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 8.0 VOLTS DC 6TH RADIO INTERFERENCE
AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 2ND RADIO INTERFERENCE
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE
AHBN INPUT TERMINAL MANUFACTURER CODE 00779
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
842920-1 0LSP2 A 1 C 9X 5 ZZ
842920-1 00779 A 9 3 A TX
Manufacturers
Part SKU Cage Manufacturer Type Status
842920-1 0LSP2 SPECTRUM CONTROL INC. F A
842920-1 00779 TYCO ELECTRONICS CORPORATION A A
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
G X B 3 06/23/1 P 8527995030 0076
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DF N SF9EH-N F
DS N I
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
B G P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DS SMS J 0 EA 0 U D
DF SMS J 0 EA 0 U SF9EH-N F
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC