| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 UNTHREADED HOLE |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE |
| AECR |
VIBRATION RESISTANCE RANGE IN HERTZ |
+10.0/+2000.0 |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
1.15 VOLTS AC 1ST RADIO INTERFERENCE |
| NHCF |
NUCLEAR HARDNESS CRITICAL FEATURE |
HARDENED |
| FEAT |
SPECIAL FEATURES |
NUCLEAR HARDNESS CRITICAL ITEMS |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 3RD RADIO INTERFERENCE |
| AFSV |
AVERAGE LIFE RATING IN HOURS |
200000.0 |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
2.600 INCHES NOMINAL |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
2.5 1ST RADIO INTERFERENCE |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
115.0 VOLTS AC 1ST RADIO INTERFERENCE |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
2.5 2ND RADIO INTERFERENCE |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
3 THREADED STUD INPUT |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
3.290 INCHES NOMINAL |
| AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 3RD RADIO INTERFERENCE |
| AHCG |
MAXIMUM TEMP RISE |
45.0 DEG CELSIUS |
| CRST |
BODY SURFACE TREATMENT |
TIN |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
2.5 3RD RADIO INTERFERENCE |
| CQRG |
BODY MATERIAL |
ALUMINUM |
| PKWT |
UNPACKAGED UNIT WEIGHT |
1.500 POUNDS |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE |
| AGAV |
END ITEM IDENTIFICATION |
VALVE-SELECTI |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
1.15 VOLTS AC 3RD RADIO INTERFERENCE |
| AFGA |
OPERATING TEMP RANGE |
-55.0/+85.0 DEG CELSIUS |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
115.0 VOLTS AC 3RD RADIO INTERFERENCE |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
400.0 1ST RADIO INTERFERENCE |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
400.0 2ND RADIO INTERFERENCE |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
1.15 VOLTS AC 2ND RADIO INTERFERENCE |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
400.0 3RD RADIO INTERFERENCE |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
115.0 VOLTS AC 2ND RADIO INTERFERENCE |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.235 INCHES NOMINAL |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE |