| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
125.0 BLANK |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS BLANK |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
3.000 INCHES NOMINAL |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
1 THREADED STUD OUTPUT |
| ABKW |
OVERALL HEIGHT |
4.000 INCHES NOMINAL |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
250.0 VOLTS SCREW ON TUBE NOT SPECIFIED AND 600.0 VOLTS 23RD BAND SUPPRESSION NOT SPECIFIED |
| AFGA |
OPERATING TEMP RANGE |
+0.0/+85.0 DEG CELSIUS |
| ADAT |
BODY WIDTH |
6.000 INCHES NOMINAL |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
3.000 INCHES NOMINAL |
| STYL |
STYLE DESIGNATOR |
RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| CQJX |
NOMINAL THREAD SIZE |
0.190 INCHES |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
8 THREADED STUD |
| ADAQ |
BODY LENGTH |
11.750 INCHES NOMINAL |
| AKEJ |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR |
UNF |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS BLANK |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
1 THREADED STUD INPUT |
| AKNA |
INCLOSURE TYPE |
ENCASED |
| CBBL |
FEATURES PROVIDED |
HUMIDITY PROOF |
| ABHP |
OVERALL LENGTH |
12.990 INCHES NOMINAL |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
400.0 BLANK |