5915-01-374-1169 ( 92272 )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5915-01-374-1169 | 5915 | 013741169 | FILTER,BAND PASS | 0020 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 BLANK |
| STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
| CBBL | FEATURES PROVIDED | SHOCK RESISTANT |
| ADAT | BODY WIDTH | 1.050 INCHES MAXIMUM |
| CQRG | BODY MATERIAL | METAL |
| CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 21.3968 MEGAHERTZ BLANK AND 21.4032 MEGAHERTZ BLANK |
| AHAJ | REFERENCE FREQUENCY PER FUNCTION | 21.4 MEGAHERTZ BLANK |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 200.0 OHMS BLANK |
| ADAQ | BODY LENGTH | 2.430 INCHES MAXIMUM |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 PIN OUTPUT |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 PIN INPUT |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 PIN GROUND |
| ABKW | OVERALL HEIGHT | 0.930 INCHES NOMINAL |
| AKNA | INCLOSURE TYPE | ENCASED |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 200.0 OHMS BLANK |
| AFGA | OPERATING TEMP RANGE | +0.0/+50.0 DEG CELSIUS |
| ADAU | BODY HEIGHT | 0.680 INCHES MAXIMUM |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 TERMINAL |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| 92272 | 14632 | A | 2 | 3 | A | TX |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| 92272 | 14632 | DRS SIGNAL SOLUTIONS INC. | A | A |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| A | X | A | 04/16/1 | P | 8527995030 | 0020 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DA | Z | Q2200X- | A | ||
| DS | N | I |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| A | A | P | X |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DA | SMS | J | 0 | EA | 0 | U | Z | Q2200X- | A |
| DS | SMS | J | 0 | EA | 0 | U | D |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|---|---|---|---|
| Q | 2 | 2 | 00 | X |
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|