| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
3 THREADED STUD OUTPUT |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
7.810 INCHES NOMINAL |
| ABKW |
OVERALL HEIGHT |
4.000 INCHES NOMINAL |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
3.250 INCHES NOMINAL |
| ADAT |
BODY WIDTH |
4.000 INCHES NOMINAL |
| STYL |
STYLE DESIGNATOR |
RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
1 THREADED STUD GROUND |
| ABTD |
MOUNTING SLOT WIDTH |
0.180 INCHES NOMINAL |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
5.0 1ST RADIO INTERFERENCE |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 CNB OHMS PER 1000 FEET |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 SLOT |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 CNB OHMS PER FOOT |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 CNB OHMS PER MILE |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
125.0 VOLTS AC 1ST RADIO INTERFERENCE AND 250.0 VOLTS AC 1ST RADIO INTERFERENCE |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
5.0 2ND RADIO INTERFERENCE |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
3 THREADED STUD INPUT |
| ADAQ |
BODY LENGTH |
7.000 INCHES NOMINAL |
| AGAV |
END ITEM IDENTIFICATION |
STAR WINDOW AIRBORNE SYSTEM AND RCT |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 3RD RADIO INTERFERENCE |
| AHCK |
FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS |
65.0 AND 65.0 AND 34.0 AND 24.0 AND 65.0 AND 60.0 |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
5.0 3RD RADIO INTERFERENCE |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
125.0 VOLTS AC 2ND RADIO INTERFERENCE AND 250.0 VOLTS AC 2ND RADIO INTERFERENCE |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
125.0 VOLTS AC 3RD RADIO INTERFERENCE AND 250.0 VOLTS AC 3RD RADIO INTERFERENCE |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
400.0 1ST RADIO INTERFERENCE |
| AKNA |
INCLOSURE TYPE |
ENCASED |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
400.0 2ND RADIO INTERFERENCE |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
400.0 3RD RADIO INTERFERENCE |
| FEAT |
SPECIAL FEATURES |
LOW PASS EMI FILTER FOR ELIMINATING POWER LINE INTERFERENCE; 3 PHASE |
| AHCJ |
FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ |
5.0 AND 0.05 AND 0.15 AND 1.5 AND 0.02 AND 50.0 |
| ABHP |
OVERALL LENGTH |
8.620 INCHES NOMINAL |