AHBZ |
VOLTAGE STANDING WAVE RATIO PER FUNCTION |
1.5 BLANK ALL FUNCTIONS |
FEAT |
SPECIAL FEATURES |
SMA FEMALE CONNECTORS, 10W AVG POWER, TEMP RANGE: OPERATIONAL, 0 TO +65 DEG C, STORAGE, -40 TO +70 DEG C. |
AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
3.870 INCHES NOMINAL |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 UNTHREADED HOLE ALL FUNCTIONS |
CRBB |
FREQUENCY BAND WIDTH PER FUNCTION |
20.00 MEGAHERTZ BLANK ALL FUNCTIONS |
AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
0.500 INCHES NOMINAL |
STYL |
STYLE DESIGNATOR |
RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
ADAT |
BODY WIDTH |
0.750 INCHES NOMINAL |
ABHP |
OVERALL LENGTH |
4.250 INCHES NOMINAL |
AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.125 INCHES NOMINAL |
ADAQ |
BODY LENGTH |
3.500 INCHES NOMINAL |
AHAJ |
REFERENCE FREQUENCY PER FUNCTION |
2000.00 MEGAHERTZ BLANK ALL FUNCTIONS |
CXCY |
PART NAME ASSIGNED BY CONTROLLING AGENCY |
CAVITY BAND PASS FILTER |
ADAU |
BODY HEIGHT |
1.980 INCHES NOMINAL |
AKNA |
INCLOSURE TYPE |
ENCASED |
AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS BLANK ALL FUNCTIONS |
CQDR |
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS |
3.5 BLANK ALL FUNCTIONS |
AGAV |
END ITEM IDENTIFICATION |
RT-1943/SPS-74(V), RADAR TRANSCEIVER; AN/SPS-74(V) PERISCOPE DETECTION RADAR; NHA 240410 USED ON PDD |