| AGVL |
SECOND CENTER TO CENTER DISTANCE BETWEEN BUSHING HOLES |
0.994 INCHES MINIMUM AND 1.009 INCHES MAXIMUM |
| ABTB |
MOUNTING HOLE DIAMETER |
0.152 INCHES NOMINAL AND 0.781 INCHES NOMINAL |
| AGVB |
CENTER TO CENTER DISTANCE BETWEEN OUTSIDE MOUNTING HOLES ALONG WIDTH |
0.052 INCHES NOMINAL |
| AGUE |
FUSE ACCOMMODATION QUANTITY |
3 |
| AGUK |
ACCOMMODATED FERRULE DIAMETER |
0.460 INCHES NOMINAL |
| ABKW |
OVERALL HEIGHT |
2.880 INCHES NOMINAL |
| AGVF |
BUSHING HOLE DIAMETER |
0.771 INCHES MINIMUM AND 0.786 INCHES MAXIMUM |
| AGUJ |
ACCOMMODATED FUSE LENGTH |
1.500 INCHES NOMINAL |
| TTQY |
TERMINAL TYPE AND QUANTITY |
3 THREADED STUD AND 3 SCREW |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81349-MIL-PRF-19207/31 GOVERNMENT SPECIFICATION |
| AAQL |
BODY STYLE |
PANEL MOUNTED TYPE |
| ABTJ |
MOUNTING HOLE QUANTITY |
3 AND 4 |
| AGVK |
CENTER TO CENTER DISTANCE BETWEEN BUSHING HOLES |
0.994 INCHES MINIMUM AND 1.009 INCHES MAXIMUM |
| ABMK |
OVERALL WIDTH |
1.190 INCHES NOMINAL |
| AJYQ |
SCREW THREAD QUANTITY PER INCH |
32.0 |
| AJYN |
SCREW THREAD DIAMETER |
0.190 INCHES NOMINAL |
| ELEC |
VOLTAGE IN VOLTS |
500.0 |
| CSNM |
FUSE TERMINAL TYPE ACCOMMODATED |
FERRULE |
| AFRG |
CONTACT MATERIAL |
BRASS |
| AGUV |
CAP DIAMETER |
0.560 INCHES NOMINAL |
| TEST |
TEST DATA DOCUMENT |
81349-MIL-PRF-19207 SPECIFICATION |
| ABHP |
OVERALL LENGTH |
2.720 INCHES NOMINAL |
| CQJL |
CURRENT CARRYING RATING IN AMPS |
30.0 |
| AGUT |
LENGTH FROM FRONT PROTRUSION TO MOUNTING SURFACE |
0.560 INCHES NOMINAL |
| AEVB |
MOUNTING HOLE STYLE |
3 BUSHING MOUNTING W/4 HOLES |
| ADZC |
ENVIRONMENTAL PROTECTION |
WATERTIGHT AND BODY SEALED |
| AGVA |
CENTER TO CENTER DISTANCE BETWEEN OUTSIDE MOUNTING HOLES ALONG LENGTH |
1.002 INCHES NOMINAL |