| CSWP |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS |
125.0 AC AND 50.0 DC |
| FREQ |
FREQUENCY IN HERTZ |
400.0 ALL LOCATIONS |
| BBRJ |
SPECIAL HANDLING FEATURE |
MAGNETIC |
| BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| AKPX |
POLE QUANTITY |
4 |
| TTQY |
TERMINAL TYPE AND QUANTITY |
10 THREADED STUD |
| ADAQ |
BODY LENGTH |
2.530 INCHES MAXIMUM |
| CPRZ |
AUXILIARY SWITCH FUNCTION AND QUANTITY |
1 ALARM |
| ZZZK |
SPECIFICATION/STANDARD DATA |
12436-A15912 GOVERNMENT SPECIFICATION |
| CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP FIRST LOCATION |
| AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
30.0 AMPERES AC ALL LOCATIONS |
| CSSX |
SWITCH CURRENT RATING AND TYPE IN AMPS |
5.0 AC AND 1.0 DC |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
1500.0 AC ALL LOCATIONS |
| CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP SECOND LOCATION |
| CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
4 TOGGLE |
| CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
EXPLOSION PROOF AND FUNGUS RESISTANT AND MOISTURE RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
0.600 MINIMUM AT 200 PCT FIRST LOCATION AND 0.600 MINIMUM AT 200 PCT SECOND LOCATION AND 0.600 MINIMUM AT 200 PCT THIRD LOCATION AND 5.000 MAXIMUM AT 200 PCT SECOND LOCATION |
| CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP THIRD LOCATION |
| CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
| AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
0.750 INCHES MINIMUM AND 0.770 INCHES MAXIMUM |
| CPRY |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT |
ONE, TWO, THREE, AND FOUR LINKED |
| AEGJ |
SWITCH CONTACT ARRANGEMENT |
SINGLE POLE, DOUBLE THROW |
| ADTV |
CASE MATERIAL |
PLASTIC |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
8 THREADED HOLE |
| CPRQ |
RESET METHOD |
MANUAL |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM |
| ADAT |
BODY WIDTH |
3.060 INCHES MAXIMUM |
| THSD |
THREAD SERIES DESIGNATOR |
UNC |
| CPRJ |
TRIP RELEASE METHOD |
MAGNETIC-HYDRAULIC ALL LOCATIONS |
| CRTK |
SWITCH TERMINAL TYPE |
TAB, SOLDER LUG |
| AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.940 INCHES MAXIMUM |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY FIRST LOCATION |
| CQSM |
SWITCH LOCATION AND POSITION DESIGNATION |
INTERNAL AT POLE THREE |
| CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
| CPRX |
ACTUATOR POSITION DESIGNATION |
AT EACH POLE |
| AAQL |
BODY STYLE |
MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
RELAY TRIP FOURTH LOCATION |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
0.750 INCHES MINIMUM AND 0.770 INCHES MAXIMUM |
| AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
2.522 INCHES MAXIMUM |
| CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
150.0 ALL LOCATIONS |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
INSTANTANEOUS FOURTH LOCATION |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
250.0 AC ALL LOCATIONS |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SECOND LOCATION |
| CMLP |
THREAD QUANTITY PER INCH |
32 |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
5.000 MAXIMUM AT 200 PCT FIRST LOCATION |
| AJEC |
BOSS HEIGHT |
0.150 INCHES MAXIMUM |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY THIRD LOCATION |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
5.000 MAXIMUM AT 200 PCT THIRD LOCATION |