BBRJ |
SPECIAL HANDLING FEATURE |
MAGNETIC |
BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
138.0 SINGLE LOCATION |
ZZZK |
SPECIFICATION/STANDARD DATA |
96906-MS24571 GOVERNMENT STANDARD |
AAQL |
BODY STYLE |
SINGLE POLE TYPE |
AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
ADAT |
BODY WIDTH |
0.760 INCHES MAXIMUM |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP SINGLE LOCATION |
TTQY |
TERMINAL TYPE AND QUANTITY |
2 TAB W/SCREW |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC SINGLE LOCATION |
ADAQ |
BODY LENGTH |
2.189 INCHES MAXIMUM |
ADTV |
CASE MATERIAL |
PLASTIC |
AKPX |
POLE QUANTITY |
1 |
CPRQ |
RESET METHOD |
MANUAL |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
115.0 AC SINGLE LOCATION AND 28.0 DC SINGLE LOCATION |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
16.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 40.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
PKWT |
UNPACKAGED UNIT WEIGHT |
0.200 POUNDS |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
5000.0 AC SINGLE LOCATION AND 5000.0 DC SINGLE LOCATION |
ABXD |
BUSHING LENGTH |
0.187 INCHES MINIMUM AND 0.249 INCHES MAXIMUM |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 THREADED HOLE |
THSD |
THREAD SERIES DESIGNATOR |
UNC |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
7.5 AMPERES AC SINGLE LOCATION AND 7.5 AMPERES DC SINGLE LOCATION |
TEST |
TEST DATA DOCUMENT |
81349-MIL-C-27715 SPECIFICATION |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
EXPLOSION PROOF AND SHOCK RESISTANT AND HUMIDITY PROOF AND SALT SPRAY PROOF AND VAPORTIGHT AND DUSTTIGHT AND SANDTIGHT AND FUNGUS PROOF |
AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
1.800 INCHES MINIMUM AND 1.820 INCHES MAXIMUM |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 PUSH-PULL |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.190 INCHES NOMINAL |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT POLE ONE |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
2.370 INCHES NOMINAL |
FREQ |
FREQUENCY IN HERTZ |
400.0 SINGLE LOCATION |
CMLP |
THREAD QUANTITY PER INCH |
32 |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SINGLE LOCATION |
CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |