| CSWP |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS |
125.0 AC AND 50.0 DC |
| FREQ |
FREQUENCY IN HERTZ |
400.0 ALL LOCATIONS |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
3.000 MINIMUM AT 150 PCT ALL LOCATIONS AND 15.000 MAXIMUM AT 150 PCT ALL LOCATIONS |
| CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
| CSSX |
SWITCH CURRENT RATING AND TYPE IN AMPS |
1.0 AC AND 0.5 DC |
| BBRJ |
SPECIAL HANDLING FEATURE |
MAGNETIC |
| BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| CPRX |
ACTUATOR POSITION DESIGNATION |
AT POLE TWO |
| AKPX |
POLE QUANTITY |
3 |
| CPRP |
ULTIMATE TRIP TIME PER POLE IN SECONDS |
6.5000 MINIMUM ALL LOCATIONS AND 30.000 MAXIMUM ALL LOCATIONS |
| AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
1.678 INCHES NOMINAL |
| THSD |
THREAD SERIES DESIGNATOR |
UNEF |
| AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
7.5 AMPERES AC ALL LOCATIONS |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
300.0 AC ALL LOCATIONS |
| CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
| CQJX |
NOMINAL THREAD SIZE |
0.375 INCHES |
| TEST |
TEST DATA DOCUMENT |
97942-128C099 DRAWING |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY ALL LOCATIONS |
| AAJE |
THREAD PITCH DIAMETERS |
+0.3503/+0.3537 INCHES |
| AEGJ |
SWITCH CONTACT ARRANGEMENT |
SINGLE POLE, DOUBLE THROW |
| CPRZ |
AUXILIARY SWITCH FUNCTION AND QUANTITY |
2 CONTROL |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
240.0 AC ALL LOCATIONS |
| CPRQ |
RESET METHOD |
MANUAL |
| AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
0.875 INCHES NOMINAL |
| ADAQ |
BODY LENGTH |
1.495 INCHES NOMINAL |
| CPRJ |
TRIP RELEASE METHOD |
MAGNETIC-HYDRAULIC ALL LOCATIONS |
| ADAT |
BODY WIDTH |
1.872 INCHES NOMINAL |
| CRTK |
SWITCH TERMINAL TYPE |
TAB, SOLDER LUG |
| ABXD |
BUSHING LENGTH |
0.375 INCHES NOMINAL |
| CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
| APNQ |
ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
| CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
HERMETICALLY SEALED |
| ADTV |
CASE MATERIAL |
METAL |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
| AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
0.625 INCHES NOMINAL |
| CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 TOGGLE |
| AAQL |
BODY STYLE |
MULTIPOLE-SINGLE ACTUATOR TYPE |
| CMLP |
THREAD QUANTITY PER INCH |
32 |
| TTQY |
TERMINAL TYPE AND QUANTITY |
6 WIRE HOOK |
| CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
115.0 ALL LOCATIONS |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
3 THREADED BUSHING |