| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
8.0 AMPERES AC SINGLE LOCATION AND 8.0 AMPERES DC SINGLE LOCATION |
| FREQ |
FREQUENCY IN HERTZ |
60.0 SINGLE LOCATION |
| BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 SCREW |
| AAQL |
BODY STYLE |
SINGLE POLE TYPE |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
230.0 AC SINGLE LOCATION AND 20.0 DC SINGLE LOCATION |
| CSWP |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS |
115.0 AC AND 50.0 DC |
| AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
| CRCF |
TRIP RELEASE AMBIENT TEMP RATING |
24.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
| CPRZ |
AUXILIARY SWITCH FUNCTION AND QUANTITY |
1 CONTROL |
| CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP SINGLE LOCATION |
| AJEC |
BOSS HEIGHT |
0.120 INCHES NOMINAL |
| ABMK |
OVERALL WIDTH |
0.997 INCHES MAXIMUM |
| CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
| AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.656 INCHES NOMINAL |
| AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
1.910 INCHES NOMINAL |
| AEGJ |
SWITCH CONTACT ARRANGEMENT |
SINGLE POLE, DOUBLE THROW |
| CRTK |
SWITCH TERMINAL TYPE |
PIN |
| CQSM |
SWITCH LOCATION AND POSITION DESIGNATION |
INTERNAL AT POLE ONE |
| ADTV |
CASE MATERIAL |
PLASTIC |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
23.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 23.000 MAXIMUM AT 300 PCT SINGLE LOCATION |
| AKPX |
POLE QUANTITY |
1 |
| CPRQ |
RESET METHOD |
MANUAL |
| APNQ |
ARC QUENCHING METHOD |
AIR |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
200.0 AC SINGLE LOCATION AND 200.0 DC SINGLE LOCATION |
| CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 PUSH BUTTON |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 THREADED HOLE |
| THSD |
THREAD SERIES DESIGNATOR |
UNC |
| CPRJ |
TRIP RELEASE METHOD |
THERMAL SINGLE LOCATION |
| CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
| CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
135.0 SINGLE LOCATION |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
1.000 INCHES NOMINAL |
| CPRX |
ACTUATOR POSITION DESIGNATION |
AT POLE ONE |
| CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
DUSTPROOF AND FUNGUS RESISTANT |
| ABHP |
OVERALL LENGTH |
1.969 INCHES NOMINAL |
| CSSX |
SWITCH CURRENT RATING AND TYPE IN AMPS |
3.0 AC AND 3.0 DC |
| CMLP |
THREAD QUANTITY PER INCH |
32 |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SINGLE LOCATION |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |