CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
SHOCK RESISTANT AND HERMETICALLY SEALED AND VIBRATION RESISTANT |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
BBRJ |
SPECIAL HANDLING FEATURE |
MAGNETIC |
FREQ |
FREQUENCY IN HERTZ |
50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
20.0 AMPERES AC ALL LOCATIONS |
CSWP |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS |
250.0 AC AND 30.0 DC |
AKPX |
POLE QUANTITY |
3 |
CPRY |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT |
ONE, TWO, AND THREE LINKED |
AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
ADAQ |
BODY LENGTH |
2.000 INCHES NOMINAL |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
3500.0 AC ALL LOCATIONS |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
3 TOGGLE |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.530 INCHES NOMINAL |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
ADAT |
BODY WIDTH |
2.265 INCHES MAXIMUM |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
2.000 INCHES MAXIMUM |
AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
0.750 INCHES NOMINAL |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY ALL LOCATIONS |
ADTV |
CASE MATERIAL |
PLASTIC |
CPRQ |
RESET METHOD |
MANUAL |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CRTK |
SWITCH TERMINAL TYPE |
QUICK DISCONNECT, MALE |
CSSX |
SWITCH CURRENT RATING AND TYPE IN AMPS |
10.0 AC AND 5.0 DC |
THSD |
THREAD SERIES DESIGNATOR |
UNC |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
6 THREADED HOLE |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
APNQ |
ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
FEAT |
SPECIAL FEATURES |
ACTUATOR WHITE WITHOUT MARKINGS |
CQSM |
SWITCH LOCATION AND POSITION DESIGNATION |
INTERNAL AT POLE TWO |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT EACH POLE |
AAQL |
BODY STYLE |
MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
TTQY |
TERMINAL TYPE AND QUANTITY |
6 QUICK DISCONNECT, MALE |
AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
1.660 INCHES NOMINAL |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
250.0 AC ALL LOCATIONS |
AAJE |
THREAD PITCH DIAMETERS |
+0.1177/+0.1214 INCHES |
AJEC |
BOSS HEIGHT |
0.130 INCHES NOMINAL |
CMLP |
THREAD QUANTITY PER INCH |
32 |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
115.0 ALL LOCATIONS |
CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |
AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
0.750 INCHES NOMINAL |