FREQ |
FREQUENCY IN HERTZ |
400.0 ALL LOCATIONS |
BBRJ |
SPECIAL HANDLING FEATURE |
MAGNETIC |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
205.0 AC ALL LOCATIONS AND 50.0 DC ALL LOCATIONS |
BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.180 INCHES MINIMUM AND 1.200 INCHES MAXIMUM |
AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT POLE TWO |
ADAT |
BODY WIDTH |
2.189 INCHES MAXIMUM |
AKPX |
POLE QUANTITY |
3 |
CPRZ |
AUXILIARY SWITCH FUNCTION AND QUANTITY |
1 ALARM |
AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
20.0 AMPERES AC ALL LOCATIONS AND 20.0 AMPERES DC ALL LOCATIONS |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
4200.0 AC ALL LOCATIONS AND 4200.0 DC ALL LOCATIONS |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
FUNGUS RESISTANT AND MOISTURE RESISTANT |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
20.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 50.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY ALL LOCATIONS |
CSWP |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS |
28.0 DC |
AEGJ |
SWITCH CONTACT ARRANGEMENT |
SINGLE POLE, DOUBLE THROW |
ADTV |
CASE MATERIAL |
PLASTIC |
CPRQ |
RESET METHOD |
MANUAL |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
145.0 ALL LOCATIONS |
ABXD |
BUSHING LENGTH |
0.235 INCHES MINIMUM AND 0.250 INCHES MAXIMUM |
THSD |
THREAD SERIES DESIGNATOR |
UNC |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
6 THREADED HOLE |
CPRJ |
TRIP RELEASE METHOD |
THERMAL-MAGNETIC ALL LOCATIONS |
TTQY |
TERMINAL TYPE AND QUANTITY |
6 TAB W/SCREW |
ADAQ |
BODY LENGTH |
2.250 INCHES MAXIMUM |
CSSX |
SWITCH CURRENT RATING AND TYPE IN AMPS |
7.0 DC |
CQSM |
SWITCH LOCATION AND POSITION DESIGNATION |
INTERNAL AT POLE THREE |
AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
1.800 INCHES MINIMUM AND 1.820 INCHES MAXIMUM |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 PUSH-PULL |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
CRCF |
TRIP RELEASE AMBIENT TEMP RATING |
25.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
ADAU |
BODY HEIGHT |
2.460 INCHES MINIMUM AND 2.480 INCHES MAXIMUM |
AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
CRTK |
SWITCH TERMINAL TYPE |
WIRE LEAD |
AAQL |
BODY STYLE |
MULTIPOLE-SINGLE ACTUATOR TYPE |
CMLP |
THREAD QUANTITY PER INCH |
32 |
CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |