FREQ |
FREQUENCY IN HERTZ |
400.0 ALL LOCATIONS |
BBRJ |
SPECIAL HANDLING FEATURE |
MAGNETIC |
CQJX |
NOMINAL THREAD SIZE |
0.250 INCHES |
BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT POLE TWO |
AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
4.710 INCHES MINIMUM AND 4.730 INCHES MAXIMUM |
AKPX |
POLE QUANTITY |
3 |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
30.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 100.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
ADAU |
BODY HEIGHT |
3.180 INCHES MINIMUM AND 3.200 INCHES MAXIMUM |
AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
140.0 ALL LOCATIONS |
AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
1.370 INCHES MINIMUM AND 1.390 INCHES MAXIMUM |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
5.240 INCHES MINIMUM AND 5.260 INCHES MAXIMUM |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY ALL LOCATIONS |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
240.0 AC ALL LOCATIONS |
AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.188 INCHES NOMINAL |
ADTV |
CASE MATERIAL |
PLASTIC |
CPRQ |
RESET METHOD |
MANUAL |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
VIBRATION RESISTANT AND SHOCK RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF AND SAND RESISTANT AND FUNGUS RESISTANT AND DUSTPROOF |
ADAT |
BODY WIDTH |
4.115 INCHES MINIMUM AND 4.135 INCHES MAXIMUM |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
5 UNTHREADED HOLE AND 6 THREADED HOLE |
THSD |
THREAD SERIES DESIGNATOR |
UNC |
TTQY |
TERMINAL TYPE AND QUANTITY |
6 COMPRESSION |
CPRJ |
TRIP RELEASE METHOD |
THERMAL-MAGNETIC ALL LOCATIONS |
AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
1.370 INCHES MINIMUM AND 1.390 INCHES MAXIMUM |
ADAQ |
BODY LENGTH |
5.990 INCHES MINIMUM AND 6.010 INCHES MAXIMUM |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
7500.0 AC ALL LOCATIONS |
CRCF |
TRIP RELEASE AMBIENT TEMP RATING |
50.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
CMLP |
THREAD QUANTITY PER INCH |
20 |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 TOGGLE |
AAQL |
BODY STYLE |
MULTIPOLE-SINGLE ACTUATOR TYPE |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
50.0 AMPERES AC ALL LOCATIONS |
AJEC |
BOSS HEIGHT |
0.180 INCHES MINIMUM AND 0.200 INCHES MAXIMUM |