| CSWP |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS |
125.0 AC AND 50.0 DC |
| AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
0.906 INCHES NOMINAL |
| CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
| CSSX |
SWITCH CURRENT RATING AND TYPE IN AMPS |
1.0 AC AND 0.5 DC |
| BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
0.055 MINIMUM AT 200 PCT ALL LOCATIONS AND 0.950 MAXIMUM AT 200 PCT ALL LOCATIONS |
| AKPX |
POLE QUANTITY |
2 |
| AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
1.828 INCHES NOMINAL |
| THSD |
THREAD SERIES DESIGNATOR |
UNEF |
| ADAQ |
BODY LENGTH |
1.562 INCHES NOMINAL |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
50.0 DC ALL LOCATIONS |
| CPRX |
ACTUATOR POSITION DESIGNATION |
BETWEEN POLE ONE AND TWO |
| CPRZ |
AUXILIARY SWITCH FUNCTION AND QUANTITY |
1 CONTROL |
| ADAT |
BODY WIDTH |
1.281 INCHES NOMINAL |
| CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
| CQJX |
NOMINAL THREAD SIZE |
0.375 INCHES |
| AEGJ |
SWITCH CONTACT ARRANGEMENT |
SINGLE POLE, DOUBLE THROW |
| CQSM |
SWITCH LOCATION AND POSITION DESIGNATION |
INTERNAL AT POLE ONE |
| CPRQ |
RESET METHOD |
MANUAL |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
INSTANTANEOUS ALL LOCATIONS AND TIME DELAY ALL LOCATIONS |
| TTQY |
TERMINAL TYPE AND QUANTITY |
4 WIRE HOOK |
| CPRJ |
TRIP RELEASE METHOD |
MAGNETIC-HYDRAULIC ALL LOCATIONS |
| CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 ALL LOCATIONS |
| CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
| CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
HERMETICALLY SEALED |
| ADTV |
CASE MATERIAL |
METAL |
| ABXD |
BUSHING LENGTH |
0.330 INCHES NOMINAL |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
| AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
0.625 INCHES NOMINAL |
| CRTK |
SWITCH TERMINAL TYPE |
WIRE HOOK |
| CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 TOGGLE |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 THREADED BUSHING W/PANEL SEAL |
| AAQL |
BODY STYLE |
MULTIPOLE-SINGLE ACTUATOR TYPE |
| CMLP |
THREAD QUANTITY PER INCH |
32 |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
500.0 DC ALL LOCATIONS |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
3.0 AMPERES DC ALL LOCATIONS |