ADAT |
BODY WIDTH |
2.041 INCHES MINIMUM AND 2.103 INCHES MAXIMUM |
BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
1.016 INCHES MINIMUM AND 1.036 INCHES MAXIMUM |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
2 TOGGLE |
FEAT |
SPECIAL FEATURES |
COMMUNICATION CENTER,PATCHING NECESSARY TO WEAPONS SYSTEM |
CSSX |
SWITCH CURRENT RATING AND TYPE IN AMPS |
5.0 AC |
CPRZ |
AUXILIARY SWITCH FUNCTION AND QUANTITY |
1 ALARM |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
30.000 MINIMUM AT 200 PCT FIRST LOCATION AND 100.000 MAXIMUM AT 200 PCT FIRST LOCATION |
AKPX |
POLE QUANTITY |
2 |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP FIRST LOCATION |
AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
AJEC |
BOSS HEIGHT |
0.209 INCHES MINIMUM AND 0.229 INCHES MAXIMUM |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
3.172 INCHES MINIMUM AND 3.296 INCHES MAXIMUM |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
AEGJ |
SWITCH CONTACT ARRANGEMENT |
SINGLE POLE, DOUBLE THROW |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 THREADED HOLE |
CQSM |
SWITCH LOCATION AND POSITION DESIGNATION |
INTERNAL AT POLE ONE |
ADTV |
CASE MATERIAL |
PLASTIC |
ADAQ |
BODY LENGTH |
5.769 INCHES MINIMUM AND 5.831 INCHES MAXIMUM |
CPRQ |
RESET METHOD |
MANUAL |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
3.516 INCHES MINIMUM AND 3.578 INCHES MAXIMUM |
AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.719 INCHES MINIMUM AND 2.781 INCHES MAXIMUM |
THSD |
THREAD SERIES DESIGNATOR |
UNC |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC ALL LOCATIONS |
CRTK |
SWITCH TERMINAL TYPE |
TAB, SOLDER LUG |
CSWP |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS |
125.0 AC |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 ALL LOCATIONS |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY FIRST LOCATION |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
APNQ |
ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT EACH POLE |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
125.0 DC ALL LOCATIONS |
AAQL |
BODY STYLE |
MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
1.016 INCHES MINIMUM AND 1.036 INCHES MAXIMUM |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
CRTL |
CRITICALITY CODE JUSTIFICATION |
FEAT |
TTQY |
TERMINAL TYPE AND QUANTITY |
6 THREADED STUD |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
5000.0 DC ALL LOCATIONS |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
SHOCK RESISTANT AND FUNGUS RESISTANT AND MOISTURE RESISTANT AND VIBRATION RESISTANT |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
RELAY TRIP SECOND LOCATION |
CPRY |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT |
ONE AND TWO LINKED |
CMLP |
THREAD QUANTITY PER INCH |
32 |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
30.0 AMPERES DC ALL LOCATIONS |
CPRL |
TRIP RELEASE CHARACTERISTIC |
INSTANTANEOUS SECOND LOCATION |
CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |