BBRJ |
SPECIAL HANDLING FEATURE |
MAGNETIC |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
125.0 DC THIRD LOCATION |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SECOND LOCATION |
ADAT |
BODY WIDTH |
3.096 INCHES NOMINAL |
BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
AKPX |
POLE QUANTITY |
4 |
TTQY |
TERMINAL TYPE AND QUANTITY |
10 THREADED STUD |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT THIRD LOCATION |
CSSX |
SWITCH CURRENT RATING AND TYPE IN AMPS |
5.0 AC |
CPRZ |
AUXILIARY SWITCH FUNCTION AND QUANTITY |
1 ALARM |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP FIRST LOCATION |
AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
60.0 AMPERES DC FIRST LOCATION |
CQSM |
SWITCH LOCATION AND POSITION DESIGNATION |
INTERNAL AT POLE FOUR |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP SECOND LOCATION |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
60.0 AMPERES DC SECOND LOCATION |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
4 TOGGLE |
ABTD |
MOUNTING SLOT WIDTH |
0.164 INCHES NOMINAL |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
FUNGUS RESISTANT AND MOISTURE RESISTANT |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP THIRD LOCATION |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERVOLTAGE FOURTH LOCATION |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
45.000 MINIMUM AT 200 PCT FIRST LOCATION AND 100.000 MAXIMUM AT 200 PCT FIRST LOCATION |
CPRY |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT |
ONE, TWO, THREE, AND FOUR LINKED |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
30.0 DC FOURTH LOCATION |
AEGJ |
SWITCH CONTACT ARRANGEMENT |
SINGLE POLE, DOUBLE THROW |
CRTK |
SWITCH TERMINAL TYPE |
PIN |
ADTV |
CASE MATERIAL |
PLASTIC |
AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
1.032 INCHES NOMINAL |
CPRQ |
RESET METHOD |
MANUAL |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
50.0 AMPERES DC THIRD LOCATION |
AJEC |
BOSS HEIGHT |
0.218 INCHES NOMINAL |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
45.000 MINIMUM AT 200 PCT SECOND LOCATION AND 100.000 MAXIMUM AT 200 PCT SECOND LOCATION |
AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.750 INCHES NOMINAL |
THSD |
THREAD SERIES DESIGNATOR |
UNC |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC ALL LOCATIONS |
CSWP |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS |
125.0 AC |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY FIRST LOCATION |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 FIRST LOCATION |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
APNQ |
ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT EACH POLE |
AAQL |
BODY STYLE |
MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
1.032 INCHES NOMINAL |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
RELAY TRIP FOURTH LOCATION |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
45.000 MINIMUM AT 200 PCT THIRD LOCATION AND 100.000 MAXIMUM AT 200 PCT THIRD LOCATION |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
8 THREADED HOLE AND 8 SLOT |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
3.546 INCHES NOMINAL |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
2.609 INCHES NOMINAL |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
5000.0 DC ALL LOCATIONS |
CPRL |
TRIP RELEASE CHARACTERISTIC |
INSTANTANEOUS FOURTH LOCATION |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SECOND LOCATION |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
125.0 DC FIRST LOCATION |
ADAQ |
BODY LENGTH |
5.844 INCHES NOMINAL |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 SECOND LOCATION |
CMLP |
THREAD QUANTITY PER INCH |
32 |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT FIRST LOCATION |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
125.0 DC SECOND LOCATION |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY THIRD LOCATION |
CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 THIRD LOCATION |