CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
11.000 MINIMUM AT 200 PCT FIRST LOCATION AND 40.000 MAXIMUM AT 200 PCT FIRST LOCATION |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
ADAT |
BODY WIDTH |
2.041 INCHES MINIMUM AND 2.103 INCHES MAXIMUM |
BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
1.016 INCHES MINIMUM AND 1.036 INCHES MAXIMUM |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
2 TOGGLE |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
3.172 INCHES MINIMUM AND 3.265 INCHES MAXIMUM |
AKPX |
POLE QUANTITY |
2 |
AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
AJEC |
BOSS HEIGHT |
0.209 INCHES MINIMUM AND 0.229 INCHES MAXIMUM |
ABTD |
MOUNTING SLOT WIDTH |
0.164 INCHES NOMINAL |
TTQY |
TERMINAL TYPE AND QUANTITY |
4 THREADED STUD |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
FUNGUS RESISTANT AND MOISTURE RESISTANT |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
ADTV |
CASE MATERIAL |
PLASTIC |
ADAQ |
BODY LENGTH |
5.769 INCHES MINIMUM AND 5.831 INCHES MAXIMUM |
CPRQ |
RESET METHOD |
MANUAL |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 THREADED HOLE AND 4 SLOT |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
3.516 INCHES MINIMUM AND 3.578 INCHES MAXIMUM |
AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.719 INCHES MINIMUM AND 2.781 INCHES MAXIMUM |
THSD |
THREAD SERIES DESIGNATOR |
UNC |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC-HYDRAULIC ALL LOCATIONS |
PKWT |
UNPACKAGED UNIT WEIGHT |
6.500 OUNCES |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 ALL LOCATIONS |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY FIRST LOCATION |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
APNQ |
ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT EACH POLE |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
125.0 DC ALL LOCATIONS |
AAQL |
BODY STYLE |
MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
1.016 INCHES MINIMUM AND 1.036 INCHES MAXIMUM |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
1000.0 DC ALL LOCATIONS |
CPRY |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT |
ONE AND TWO LINKED |
CMLP |
THREAD QUANTITY PER INCH |
32 |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
40.0 AMPERES DC FIRST LOCATION |
CPRL |
TRIP RELEASE CHARACTERISTIC |
INSTANTANEOUS SECOND LOCATION |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
18.0 AMPERES DC SECOND LOCATION |
CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |