5925-00-175-5237 ( P7767053P10 , AT21050 , 29478 )
NSN Information
NSN | FSC | NIIN | Item Name | INC |
---|---|---|---|---|
5925-00-175-5237 | 5925 | 001755237 | CIRCUIT BREAKER | 0013 |
NSN Features
MRC | Parameter | Characteristics |
---|---|---|
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS AND 240.0 DC ALL LOCATIONS |
AKPX | POLE QUANTITY | 2 |
TTQY | TERMINAL TYPE AND QUANTITY | 4 THREADED STUD |
CPRJ | TRIP RELEASE METHOD | THERMAL ALL LOCATIONS |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 50.0 AMPERES AC ALL LOCATIONS AND 50.0 AMPERES DC ALL LOCATIONS |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.188 INCHES NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
CPRQ | RESET METHOD | MANUAL |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 122.0 ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 18.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 105.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC ALL LOCATIONS AND 5000.0 DC ALL LOCATIONS |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
Manufacturing Part Numbers (SKUs)
Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
---|---|---|---|---|---|---|---|
P7767053P10 | 60969 | A | 2 | 5 | 1 | TX | |
AT21050 | 60969 | A | 2 | 3 | 3 | TX | |
29478 | 80064 | A | 2 | 3 | 1 | TX |
Manufacturers
Part SKU | Cage | Manufacturer | Type | Status |
---|---|---|---|---|
P7767053P10 | 60969 | GENERAL ELECTRIC CO | A | A |
AT21050 | 60969 | GENERAL ELECTRIC CO | A | A |
29478 | 80064 | NAVAL SHIP SYSTEMS COMMAND | A | A |
FLIS Identification
PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
---|---|---|---|---|---|---|---|---|---|---|
U | X | A | 01/01/1 | P | 8536200040 | 0013 |
FLIS Management
MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
---|---|---|---|---|---|
DS | I | ||||
DN | 9B----- | N |
Demilitarization Codes & Management
DML | PMI | HMIC | ADP | CC | ESDC |
---|---|---|---|---|---|
A | U | P | X |
Miscellaneous Management
MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
---|---|---|---|---|---|---|---|---|---|
DN | SMS | X | 1 | EA | 0 | U | 9B----- | N | |
DS | SMS | X | 1 | EA | 0 | U | D |
Management Control Army
MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
---|
Freight
NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
---|---|---|---|---|---|---|---|---|---|---|---|---|
061300 | X | 34410 | P | 658 | Z | 9 | A | H | Z | CIRCUIT BREAKER/SWITCH NOI |