ADAT |
BODY WIDTH |
1.530 INCHES NOMINAL |
AJEC |
BOSS HEIGHT |
0.150 INCHES NOMINAL |
BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
2 TOGGLE |
AKPX |
POLE QUANTITY |
2 |
ADAQ |
BODY LENGTH |
2.530 INCHES NOMINAL |
AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
CQJX |
NOMINAL THREAD SIZE |
0.190 INCHES |
AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.060 INCHES NOMINAL |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
FUNGUS RESISTANT AND MOISTURE RESISTANT |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
250.0 AC SECOND LOCATION |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
0.750 INCHES NOMINAL |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
250.0 DC FIRST LOCATION |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
4.000 MINIMUM AT 200 PCT SECOND LOCATION AND 10.000 MAXIMUM AT 200 PCT SECOND LOCATION |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 THREADED HOLE |
ADTV |
CASE MATERIAL |
PLASTIC |
TTQY |
TERMINAL TYPE AND QUANTITY |
7 THREADED STUD |
CPRQ |
RESET METHOD |
MANUAL |
APNQ |
ARC QUENCHING METHOD |
AIR |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
3000.0 AC SECOND LOCATION |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SHUNT TRIP SECOND LOCATION |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
2.630 INCHES NOMINAL |
THSD |
THREAD SERIES DESIGNATOR |
UNC |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRL |
TRIP RELEASE CHARACTERISTIC |
INSTANTANEOUS FIRST LOCATION |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
RELAY TRIP FIRST LOCATION |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
200.0 MILLIAMPERES DC FIRST LOCATION |
FREQ |
FREQUENCY IN HERTZ |
60.0 SECOND LOCATION |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT EACH POLE |
AAQL |
BODY STYLE |
MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
18.0 AMPERES AC SECOND LOCATION |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SECOND LOCATION |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.940 INCHES NOMINAL |
CPRY |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT |
ONE AND TWO LINKED |
CMLP |
THREAD QUANTITY PER INCH |
32 |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
3000.0 DC FIRST LOCATION |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
115.0 ALL LOCATIONS |
AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
0.750 INCHES NOMINAL |