FREQ |
FREQUENCY IN HERTZ |
400.0 ALL LOCATIONS |
ADAT |
BODY WIDTH |
2.250 INCHES MAXIMUM |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
BBRJ |
SPECIAL HANDLING FEATURE |
MAGNETIC |
CQQR |
THREAD PITCH IN MILLIMETERS |
0.50 |
AJEC |
BOSS HEIGHT |
0.150 INCHES NOMINAL |
THSD |
THREAD SERIES DESIGNATOR |
ISO S |
BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
AKPX |
POLE QUANTITY |
3 |
CPRZ |
AUXILIARY SWITCH FUNCTION AND QUANTITY |
1 ALARM |
CPRY |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT |
ONE, TWO, AND THREE LINKED |
CSWP |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS |
250.0 AC AND 50.0 DC |
AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
CQJX |
NOMINAL THREAD SIZE |
3.0 MILLIMETERS |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
3 TOGGLE |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
5000.0 AC ALL LOCATIONS |
AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
0.750 INCHES NOMINAL |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY ALL LOCATIONS |
PKWT |
UNPACKAGED UNIT WEIGHT |
11.100 OUNCES |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
2.475 INCHES NOMINAL |
AEGJ |
SWITCH CONTACT ARRANGEMENT |
SINGLE POLE, DOUBLE THROW |
CSSX |
SWITCH CURRENT RATING AND TYPE IN AMPS |
10.0 AC AND 3.0 DC |
CQSM |
SWITCH LOCATION AND POSITION DESIGNATION |
INTERNAL AT POLE ONE |
ADTV |
CASE MATERIAL |
PLASTIC |
CPRQ |
RESET METHOD |
MANUAL |
CRTK |
SWITCH TERMINAL TYPE |
QUICK DISCONNECT, MALE |
AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
6 THREADED HOLE |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC ALL LOCATIONS |
ADAQ |
BODY LENGTH |
2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
APNQ |
ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT EACH POLE |
AAQL |
BODY STYLE |
MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
2.5 AMPERES AC ALL LOCATIONS |
TTQY |
TERMINAL TYPE AND QUANTITY |
6 THREADED STUD |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
MOISTURE RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
250.0 AC ALL LOCATIONS |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 22.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.940 INCHES NOMINAL |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
115.0 ALL LOCATIONS |
AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
0.750 INCHES NOMINAL |