AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
4.349 INCHES MINIMUM AND 4.369 INCHES MAXIMUM |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
FREQ |
FREQUENCY IN HERTZ |
60.0 ALL LOCATIONS |
AJEC |
BOSS HEIGHT |
0.208 INCHES MINIMUM AND 0.228 INCHES MAXIMUM |
PKWT |
UNPACKAGED UNIT WEIGHT |
36.000 OUNCES |
BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
SHOCK RESISTANT AND VIBRATION RESISTANT |
AKPX |
POLE QUANTITY |
3 |
AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
1.490 INCHES MINIMUM AND 1.510 INCHES MAXIMUM |
CPRY |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT |
ONE, TWO, AND THREE LINKED |
AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
ADAU |
BODY HEIGHT |
2.678 INCHES MINIMUM AND 2.698 INCHES MAXIMUM |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
120.0 ALL LOCATIONS |
CQJX |
NOMINAL THREAD SIZE |
0.190 INCHES |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
3 TOGGLE |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CPRL |
TRIP RELEASE CHARACTERISTIC |
INSTANTANEOUS ALL LOCATIONS |
ADAT |
BODY WIDTH |
4.490 INCHES MINIMUM AND 4.510 INCHES MAXIMUM |
ADTV |
CASE MATERIAL |
PLASTIC |
AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
4.349 INCHES MINIMUM AND 4.369 INCHES MAXIMUM |
CPRQ |
RESET METHOD |
MANUAL |
THSD |
THREAD SERIES DESIGNATOR |
UNF |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
75.0 AMPERES AC ALL LOCATIONS AND 75.0 AMPERES DC ALL LOCATIONS |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
6 THREADED HOLE |
ADAQ |
BODY LENGTH |
5.240 INCHES MINIMUM AND 5.260 INCHES MAXIMUM |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC-HYDRAULIC ALL LOCATIONS |
TTQY |
TERMINAL TYPE AND QUANTITY |
6 COMPRESSION |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
5000.0 AC ALL LOCATIONS AND 5000.0 DC ALL LOCATIONS |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
APNQ |
ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT EACH POLE |
AAQL |
BODY STYLE |
MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
CMLP |
THREAD QUANTITY PER INCH |
32 |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
250.0 AC ALL LOCATIONS AND 125.0 DC ALL LOCATIONS |
AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
1.490 INCHES MINIMUM AND 1.510 INCHES MAXIMUM |