CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
125.0 AC FIRST LOCATION |
AJEC |
BOSS HEIGHT |
0.150 INCHES NOMINAL |
FREQ |
FREQUENCY IN HERTZ |
60.0 ALL LOCATIONS |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
2.5 AMPERES AC SECOND LOCATION |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
5000.0 AC SECOND LOCATION AND 5000.0 DC SECOND LOCATION |
ADAT |
BODY WIDTH |
2.500 INCHES NOMINAL |
AKPX |
POLE QUANTITY |
3 |
CPRY |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT |
ONE, TWO, AND THREE LINKED |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
3 TOGGLE |
AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.062 INCHES NOMINAL |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
250.0 AC SECOND LOCATION |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CPRL |
TRIP RELEASE CHARACTERISTIC |
INSTANTANEOUS ALL LOCATIONS |
AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
0.750 INCHES NOMINAL |
CPRZ |
AUXILIARY SWITCH FUNCTION AND QUANTITY |
2 ALARM |
AEGJ |
SWITCH CONTACT ARRANGEMENT |
SINGLE POLE, DOUBLE THROW |
ADAQ |
BODY LENGTH |
2.500 INCHES NOMINAL |
CQSM |
SWITCH LOCATION AND POSITION DESIGNATION |
INTERNAL AT POLE ONE |
CPRQ |
RESET METHOD |
MANUAL |
THSD |
THREAD SERIES DESIGNATOR |
UNC |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
6 THREADED HOLE |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
2.640 INCHES NOMINAL |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC ALL LOCATIONS |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
5000.0 AC THIRD LOCATION AND 5000.0 DC THIRD LOCATION |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT EACH POLE |
AAQL |
BODY STYLE |
MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ADTV |
CASE MATERIAL |
METAL |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
TTQY |
TERMINAL TYPE AND QUANTITY |
6 THREADED STUD |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
50.0 DC THIRD LOCATION |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.940 INCHES NOMINAL |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
5000.0 AC FIRST LOCATION AND 5000.0 DC FIRST LOCATION |
CMLP |
THREAD QUANTITY PER INCH |
32 |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
5.0 AMPERES AC FIRST LOCATION |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
115.0 ALL LOCATIONS |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
1.0 AMPERES DC THIRD LOCATION |
CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |
AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
0.750 INCHES NOMINAL |