| FREQ |
FREQUENCY IN HERTZ |
400.0 ALL LOCATIONS |
| CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
| AGAV |
END ITEM IDENTIFICATION |
USED IN CIRCUIT BREAKER NSN 5925-01-075-8931 ONBOARD 270 FT. WMEC COAST GUARD VESSELS |
| CPSF |
ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS |
+625.0/+1300.0 AC ALL LOCATIONS |
| AKPX |
POLE QUANTITY |
3 |
| ABKW |
OVERALL HEIGHT |
4.500 INCHES NOMINAL |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
150.0 AMPERES AC ALL LOCATIONS |
| CPRJ |
TRIP RELEASE METHOD |
THERMAL ALL LOCATIONS |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.375 INCHES NOMINAL |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY ALL LOCATIONS |
| CBBL |
FEATURES PROVIDED |
ADJUSTABLE TRIP RELEASE |
| AAQL |
BODY STYLE |
RECTANGULAR DIMENSIONAL ENVELOPE |
| CPRP |
ULTIMATE TRIP TIME PER POLE IN SECONDS |
3600.000 NOMINAL ALL LOCATIONS |
| ABMK |
OVERALL WIDTH |
8.250 INCHES NOMINAL |
| CRCF |
TRIP RELEASE AMBIENT TEMP RATING |
50.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
3 UNTHREADED HOLE |
| TTQY |
TERMINAL TYPE AND QUANTITY |
6 SCREW |
| ABHP |
OVERALL LENGTH |
4.500 INCHES NOMINAL |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
| CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
150.0 ALL LOCATIONS |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
100.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 300.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
500.0 AC ALL LOCATIONS |