| CSWP |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS |
125.0 AC AND 50.0 DC |
| FREQ |
FREQUENCY IN HERTZ |
60.0 SINGLE LOCATION |
| BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| CPRJ |
TRIP RELEASE METHOD |
MAGNETIC-HYDRAULIC SINGLE LOCATION |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
125.0 AC SINGLE LOCATION |
| CPRZ |
AUXILIARY SWITCH FUNCTION AND QUANTITY |
1 ALARM |
| AAQL |
BODY STYLE |
SINGLE POLE TYPE |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
5.0 AMPERES AC SINGLE LOCATION |
| AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 THREADED STUD |
| ADAT |
BODY WIDTH |
0.750 INCHES NOMINAL |
| CPRP |
ULTIMATE TRIP TIME PER POLE IN SECONDS |
18.000 MINIMUM SINGLE LOCATION AND 70.000 MAXIMUM SINGLE LOCATION |
| CSSX |
SWITCH CURRENT RATING AND TYPE IN AMPS |
5.0 AC AND 1.0 DC |
| CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP SINGLE LOCATION |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.062 INCHES NOMINAL |
| CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
| AEGJ |
SWITCH CONTACT ARRANGEMENT |
SINGLE POLE, DOUBLE THROW |
| ADAQ |
BODY LENGTH |
2.500 INCHES NOMINAL |
| CQSM |
SWITCH LOCATION AND POSITION DESIGNATION |
INTERNAL AT POLE ONE |
| ADTV |
CASE MATERIAL |
PLASTIC |
| AKPX |
POLE QUANTITY |
1 |
| AJEC |
BOSS HEIGHT |
0.140 INCHES NOMINAL |
| CPRQ |
RESET METHOD |
MANUAL |
| APNQ |
ARC QUENCHING METHOD |
AIR |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 THREADED HOLE |
| THSD |
THREAD SERIES DESIGNATOR |
UNC |
| AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.938 INCHES NOMINAL |
| CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
MOISTURE RESISTANT AND FUNGUS RESISTANT AND EXPLOSION RESISTANT |
| CRTK |
SWITCH TERMINAL TYPE |
TAB, SOLDER LUG |
| CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
1.400 MINIMUM AT 300 PCT SINGLE LOCATION AND 10.000 MAXIMUM AT 200 PCT SINGLE LOCATION AND 10.000 MINIMUM AT 150 PCT SINGLE LOCATION AND 4.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 30.000 MAXIMUM AT 150 PCT SINGLE LOCATION AND 4.000 MAXIMUM AT 300 PCT SINGLE LOCATION |
| CPRX |
ACTUATOR POSITION DESIGNATION |
AT POLE ONE |
| CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 TOGGLE |
| CMLP |
THREAD QUANTITY PER INCH |
32 |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SINGLE LOCATION |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
2000.0 AC SINGLE LOCATION |
| CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 SINGLE LOCATION |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |
| AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
2.611 INCHES NOMINAL |