| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
0.800 MINIMUM AT 200 PCT SINGLE LOCATION AND 4.000 MAXIMUM AT 200 PCT SINGLE LOCATION AND 0.300 MINIMUM AT 300 PCT SINGLE LOCATION AND 1.000 MAXIMUM AT 300 PCT SINGLE LOCATION AND 0.070 MINIMUM AT 400 PCT SINGLE LOCATION AND 0.500 MAXIMUM AT 400 PCT SINGLE LOCATION |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 THREADED BUSHING |
| THSD |
THREAD SERIES DESIGNATOR |
UNEF |
| ABKW |
OVERALL HEIGHT |
1.605 INCHES NOMINAL |
| ABHP |
OVERALL LENGTH |
1.500 INCHES NOMINAL |
| CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
| CQJX |
NOMINAL THREAD SIZE |
0.375 INCHES |
| CPRJ |
TRIP RELEASE METHOD |
MAGNETIC SINGLE LOCATION |
| ADTV |
CASE MATERIAL |
PLASTIC |
| AKPX |
POLE QUANTITY |
1 |
| CPRQ |
RESET METHOD |
MANUAL |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE HOOK |
| CPRW |
ACTUATOR FUNCTION |
RESET |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
50.0 DC SINGLE LOCATION |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
750.0 DC SINGLE LOCATION |
| APNQ |
ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
5.0 AMPERES DC SINGLE LOCATION |
| CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 TOGGLE |
| CMLP |
THREAD QUANTITY PER INCH |
32 |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SINGLE LOCATION |
| CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 SINGLE LOCATION |