5925-00-969-8672 ( SM3-3-240VAC400C2 , 260-3230-000 , 260-3230-00 )

NSN Information
NSN FSC NIIN Item Name INC
5925-00-969-8672 5925 009698672 CIRCUIT BREAKER 0013
NSN Features
MRC Parameter Characteristics
ADAT BODY WIDTH 0.567 INCHES MINIMUM AND 0.629 INCHES MAXIMUM
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.870 INCHES MINIMUM AND 0.880 INCHES MAXIMUM
PRMT PRECIOUS MATERIAL SILVER
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
AAQL BODY STYLE SINGLE POLE TYPE
THSD THREAD SERIES DESIGNATOR UNEF
AFJN FRAGILITY FACTOR MODERATELY RUGGED
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 240.0 AC SINGLE LOCATION
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1.524 INCHES MINIMUM AND 1.586 INCHES MAXIMUM
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION
ADAQ BODY LENGTH 1.448 INCHES MINIMUM AND 1.510 INCHES MAXIMUM
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CQJX NOMINAL THREAD SIZE 0.375 INCHES
CPRJ TRIP RELEASE METHOD MAGNETIC SINGLE LOCATION
AKPX POLE QUANTITY 1
CPRQ RESET METHOD MANUAL
TTQY TERMINAL TYPE AND QUANTITY 2 WIRE HOOK
ABXD BUSHING LENGTH 0.360 INCHES MINIMUM AND 0.380 INCHES MAXIMUM
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 300.0 AC SINGLE LOCATION
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 3.0 AMPERES AC SINGLE LOCATION
CPRW ACTUATOR FUNCTION TRIP-RESET
APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED HERMETICALLY SEALED
ADTV CASE MATERIAL METAL
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.600 MAXIMUM AT 200 PCT SINGLE LOCATION AND 0.010 MINIMUM AT 400 PCT SINGLE LOCATION AND 0.040 MINIMUM AT 300 PCT SINGLE LOCATION AND 0.190 MINIMUM AT 200 PCT SINGLE LOCATION AND 0.190 MAXIMUM AT 300 PCT SINGLE LOCATION AND 0.080 MAXIMUM AT 400 PCT SINGLE LOCATION
FREQ FREQUENCY IN HERTZ 400.0 SINGLE LOCATION
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING W/PANEL SEAL
CMLP THREAD QUANTITY PER INCH 32
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 SINGLE LOCATION
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
SM3-3-240VAC400C2 74193 H 9 5 E TX
260-3230-000 13499 A 2 3 5 TX
260-3230-00 13499 A 2 7 A TX
Manufacturers
Part SKU Cage Manufacturer Type Status
SM3-3-240VAC400C2 74193 EATON CORP A H
260-3230-000 13499 ROCKWELL COLLINS INC. F A
260-3230-00 13499 ROCKWELL COLLINS INC. F A
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
S X A 06/15/1 P 8536200040 0013
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061300 X 34410 P P 658 Z 9 A H Z CIRCUIT BREAKER/SWITCH NOI